GE AJCQ08AC Owners Manual - Page 9
Notice
View all GE AJCQ08AC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
GEAppliances.com Terminal Connections Remote Thermostat - Class 2 (on some models) The controls are located under a plastic cover behind the front grille. E_] Removethe front grille. Seethe Front Grille _u section of Coreand Cleaning. r_ Removethe screws securing the plastic cover over the wiring connections. Set aside screws and plastic cover. I-j] To make wiring connections, insert the wires into the bottom of the terminals and tighten screws securelg. [] After all desired connections have been made, replace the plastic cover and front grille. The owner is responsible for making all connections and setting the appropriate dip switches. When connected, the unit will be controlled by a remote thermostat. NOTE:Thenumber 3 dip switch must be in the enabled (UPJposition to activate the remote thermostat. (Seethe installation instructions supplied with the remote thermostat.) IMPORTANT: The thermostat connections provide 24 V AConly. If using a digital/electronic wall thermostat, ensure it is compatible with 2/4VACsignal. See the Installation Instructions for the wall thermostat. NOTICE: Damage to a wall thermostat or to the electronics can result from improper connections. Specialcare must be used in connecting the wires. No line voltage connections should be made to any circuit. Isolateall wires in building from line voltage. / Red- 24 V AC only • Green- Low SpeedFan Green- High SpeedFan Yellow- Compressor White - Heater Common- Ground Terminal onnectlons location nderfront grille 9