GE AZ41E12DAC Owners Manual - Page 3
About the controls on your Zoneline.
View all GE AZ41E12DAC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
Safety Instructions About the controls on your Zoneline. GEAppliances.com Operating Instructions Care and Cleaning Troubleshooting Tips TEMP CONTROL FAN, MODE & SLEEP OPERATION Controls Temp Control The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. Press the ▲ pad to raise the temperature. Press the ▼ pad to lower the temperature. NOTE: The display shows the set temperature, not the room temperature. Sleep Press to set the air conditioner to run for 8 hours before it automatically returns to the previous setting. When in the cooling mode and the sleep timer is set, the set temperature will automatically increase 2°F after the second hour then 1°F each hour over the next two hours. Also, the fan speed will change to low. When in the heating mode, the set temperature will decrease in the same manner. To cancel the sleep mode, press the MODE pad or the SLEEP pad a second time. Fan, Mode and Operation Control FAN-Sets the fan operation for HIGH, LOW or AUTO speed. When set at AUTO, it automatically switches between LOW and HIGH as room temperature changes. MODE-COOL-For cooling FAN-For fan-only operation HEAT-For heating OPERATION-ON/STOP-Turns the unit on or off. Power remains connected to the Zoneline. The Freeze/Heat Sentinel features still function if active.See the freezer/Heat sentinel section on page 6. NOTE: the temperature display will flash to indicate a possible unit malfunction. set operation control to STOP and then restart the unit. if the flashing light reappears within 30 minutes, call for service. Quick Heat Recovery Activates each time the thermostat is switched from STOP or COOL mode to HEAT mode. Electric heaters are energized until the thermostat set point is reached. On heat pump models, the heat pump operation will resume at the next call for heat. About Your Heat Pump (6100 Series only) Heat pumps can save money by removing heat from the outside air-even when the outside temperature is below freezing-and releasing that heat indoors. To get the best performance from your heat pump, don't change the room thermostat very often. Raising the heat setting 2-3 degrees will cause the Zoneline to use its electric heating elements in order to reach the new temperature setting quickly. There is a 3-minute minimum compressor run time at any setting to prevent short cycling. The indoor fan motor starts before the compressor and stops after the compressor cycles off. When the outdoor temperature is lower than 25°F, heat is provided by the electric heater in the air conditioner instead of by the heat pump. The electric heating elements use much more electricity than heat pumps and cost more to operate. 3 Consumer Support