GE CSB42WSKSS Quick Specs - Page 2

CSB42WSK

Page 2 highlights

CSB42WSK GE Café™ Series 42" Built-In Side-By-Side Refrigerator DIMENSIONS AND INSTALLATION INFORMATION 24" GROUNDING THE REFRIGERATOR SIDE PANELS IMPORTANT-PLEASE READ CAREFULLY FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. The power supply cord of this appliance is equipped with a three-prong (grounding) plug which mates with a standard three-prong (grounding) wall receptacle to minimize the possibility of electric shock hazard from this appliance. Side panels (not supplied) must be used whenever the sides of the refrigerator will be exposed. The 1/4" side panels will slip into *84" the side case trim. Order side panels from your cabinet manufacturer. *Depending on installation height. Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded. *3" TO 4" 1-1/2" Where a standard 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet. DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD. DO NOT USE AN ADAPTER PLUG TO CONNECT THE REFRIGERATOR TO A 2-PRONG OUTLET. DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE. FLOORING For proper installation, this refrigerator must be placed on a level surface of hard material that is at the same height as the rest of the flooring. This surface should be strong enough to support a fully loaded refrigerator, or approximately 1500 lbs. NOTE: Protect the finish of the flooring. Cut a large section of the cardboard carton and place under the refrigerator where you are working. WATER AND ELECTRICAL LOCATIONS The opening must be prepared with the electrical and water supply located as shown. THE INSTALLATION SPACE 3" *Finished Width 7" 84 1/2" max 83 1/2" min Finished Opening Electrical 7" Area 74" From Floor to Bottom 24" of Electrical 5" Water Supply 3 1/2" 5" 3 1/2" *The finished cutout width must be: 41-1/2" for 42" models THE CUTOUT DEPTH MUST BE 24" The refrigerator will project forward, slightly beyond adjacent cabinets, depending on your installation. ADDITIONAL SPECIFICATIONS A 120 volt, 60Hz, 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical must be located on rear wall as shown. NOTE: GFI (ground fault interrupter) is not recommended. Water line can enter the opening through the floor or rear wall. The water line installed should be 1/4" O.D. copper tubing or GE SmartConnect™ tubing between the cold water line and water connection location. The line should be long enough to extend to the front of the refrigerator. Installation of an easily accessible shutoff valve in the water line is required. For answers to your Monogram, GE Profile™ Series or GE® Series appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000. Total volume and shelf area are calculated by the Association of Home Appliance Manufacturers' standards. Listed by Underwriters Laboratories Specification Revised 10/15

  • 1
  • 2
  • 3

CSB42WSK
GE Café
Series 42" Built-In Side-By-Side Refrigerator
Total volume and shelf
area are calculated by
the Association of Home
Appliance Manufacturers’
standards.
Listed by
Underwriters
Laboratories
Specification Revised 10/15
For answers to your Monogram, GE Profile
Series
or GE
®
Series appliance questions, visit our website
at geappliances.com or call GE Answer Center
®
service, 800.626.2000.
24"
*84"
*3" TO 4"
1-1/2"
FLOORING
For proper installation, this refrigerator must be
placed on a level surface of hard material that
is at the same height as the rest of the flooring.
This surface should be strong enough to support
a fully loaded refrigerator, or approximately 1500 lbs.
NOTE:
Protect the finish
of the flooring. Cut a
large section of the cardboard carton and place
under the refrigerator where you are working.
WATER AND ELECTRICAL LOCATIONS
The opening must
be prepared with the
electrical and water supply located as shown.
GROUNDING THE REFRIGERATOR
IMPORTANT—PLEASE READ CAREFULLY
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.
The power supply cord of this appliance is
equipped with a three-prong (grounding) plug
which mates with a standard three-prong
(grounding) wall receptacle to minimize the
possibility of electric shock hazard from this
appliance.
Have the wall outlet and circuit checked by a
qualified electrician to make sure the outlet is
properly grounded.
Where a standard 2-prong wall outlet is
encountered, it is your personal responsibility
and obligation to have it replaced with a properly
grounded 3-prong wall outlet.
DO NOT, UNDER ANY
CIRCUMSTANCES, CUT
OR REMOVE THE THIRD
(GROUND) PRONG FROM
THE POWER CORD.
DO NOT USE AN ADAPTER PLUG
TO CONNECT THE REFRIGERATOR
TO A 2-PRONG OUTLET.
DO NOT USE AN EXTENSION CORD
WITH THIS APPLIANCE.
*Finished Width
Electrical
Area
84 1/2" max
83 1/2" min
Finished
Opening
74"
From Floor
to Bottom
of Electrical
24"
5"
5"
3 1/2"
Water
Supply
3 1/2"
3"
7"
7"
THE CUTOUT DEPTH MUST BE 24"
The refrigerator will project forward, slightly beyond
adjacent cabinets, depending on your installation.
ADDITIONAL SPECIFICATIONS
A 120 volt, 60Hz, 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be located
on rear wall as shown.
NOTE:
GFI (ground fault interrupter) is not recommended.
Water line can enter the opening through the floor or
rear wall. The water line installed should be 1/4" O.D.
copper tubing or GE SmartConnect
tubing between
the cold water line and water connection location. The
line should be long enough to extend to the front of the
refrigerator. Installation of an easily accessible shutoff
valve in the water line is required.
THE INSTALLATION SPACE
DIMENSIONS AND INSTALLATION
INFORMATION
SIDE PANELS
Side panels (not supplied)
must be used whenever
the sides of the refrigerator
will be exposed. The 1/4"
side panels will slip into
the side case trim. Order
side panels from your
cabinet manufacturer.
*Depending on installation height.
*The finished
cutout width must
be: 41-1/2" for
42" models