Operating Instructions Installation Instructions Safety Instructions Installing the water heater. Hot and Cold Pipe Insulation Installation HOT FE I L ER EV L AV COLD HOT FE I L ER EV L AV COLD Typical vertical piping arrangement Typical horizontal piping arrangement Typical side piping arrangement For increased energy efficiency, some water heaters have been supplied with two 24" sections of pipe insulation. Please install the insulation, according to the illustrations above, that best meets your requirements. CAUTION: Ensure the T&P Valve opening is not obstructed by the insulation. Relief Valve Insulation Installation HOT FE I L ER EV L AV COLD Typical top connection arrangement For increased energy efficiency, some water heaters have been supplied with a 2-3/8" section of pipe insulation. Please install the insulation, according to the illustrations above, that best meets your requirements. Typical side connection arrangement Slip the insulation cover over the T&P Valve through the center hole and align the hole in the side with the opening of the T&P Valve. Heat Traps For increased energy efficiency, some water heaters have been supplied with factory installed heat traps in the hot outlet line and cold water inlet line. NOTICE: Do not apply heat to the HOT or COLD water connections. If sweat connections are used, sweat tubing to adapter before fitting adapter to the water connections on heater. Any heat applied to the water supply fittings will permanently damage the dip tube and/or heat traps. Care and Cleaning Troubleshooting Tips Customer Service 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

10
Installing the water heater.
Hot and Cold Pipe Insulation Installation
For increased energy efficiency, some
water heaters have been supplied with
two 24” sections of pipe insulation.
Please install the insulation, according
to the illustrations above, that best
meets your requirements.
Heat Traps
For increased energy efficiency, some
water heaters have been supplied with
factory installed heat traps in the hot
outlet line and cold water inlet line.
NOTICE: Do not apply heat to the HOT or
COLD water connections. If sweat
connections are used, sweat tubing to
adapter before fitting adapter to the water
connections on heater. Any heat applied
to the water supply fittings will
permanently damage the dip tube and/or
heat traps.
Customer Service
Troubleshooting Tips
Care and Cleaning
Operating Instructions
Installation Instructions
Safety Instructions
R
E
L
I
E
F
V
A
L
V
E
COLD
HOT
Typical vertical piping
arrangement
R
E
L
I
E
F
V
A
L
V
E
COLD
HOT
Typical horizontal piping
arrangement
Typical side piping
arrangement
For increased energy efficiency, some
water heaters have been supplied with
a 2-3/8” section of pipe insulation.
Please install the insulation, according
to the illustrations above, that best
meets your requirements.
Slip the insulation cover over the T&P
Valve through the center hole and align
the hole in the side with the opening of
the T&P Valve.
R
E
L
I
E
F
V
A
L
V
E
COLD
HOT
Typical top connection arrangement
Typical side connection arrangement
Relief Valve Insulation Installation
CAUTION: Ensure the
T&P Valve opening is not
obstructed by the
insulation.