Installation Instructions REQUIREMENTS FOR ALCOVE OR CLOSET INSTALLATION WARNING - Explosion Hazard Keep flammable materials and vapors, such as gasoline, away from dryer. Place dryer at least 18" (46 cm) above the floor for a garage installation. Failure to do so can result in death, explosion, or fire. • If the dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. • The dryer MUST be vented to the outdoors. See the EXHAUSTING THE DRYER section. • Minimum clearance between dryer cabinet and adjacent walls or other surfaces is: 0" either side 3" front 3" rear • Minimum vertical space from dryer to overhead shelves, cabinets, ceilings, etc., is 1" on top. • Consideration must be given to provide adequate clearance for installation and service. • Closet doors must be louvered or otherwise ventilated and have at least 60 square inches of open area. If the closet contains both a washer and a dryer, doors must contain a minimum of 120 square inches of open area. NOTE: WHEN THE EXHAUST DUCT IS LOCATED IN THE REAR OF THE DRYER, THE CONFIGURATION OF THE DUCTING MAY REQUIRE GREATER THAN 3" OF REAR CLEARANCE. MINIMUM CLEARANCE OTHER THAN ALCOVE OR CLOSET INSTALLATION Minimum clearance to combustible surfaces and for air opening are: 0" both sides, 1" front and 3" rear. Consideration must be given to provide adequate clearance for installation and service. MOBILE OR MANUFACTURED HOME INSTALLATION • Installation must conform to the MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24, PART 32-80 or Standard CAN/CSA-Z240 MH, or, when such standard is not applicable, with AMERICAN NATIONAL STANDARD FOR MOBILE HOME, ANSI/NFPA NO. 501B. • The dryer MUST be vented to the outdoors. The exhaust vent must be securely fastened to a non-combustible portion of the mobile home. • The vent MUST NOT be terminated beneath a mobile or manufactured home. • The vent duct material MUST BE METAL. • KIT 14-D346-33 MUST be used to attach the dryer securely to the structure. • The vent MUST NOT be connected to any other duct, vent or chimney. • Do not use sheet metal screws or other fastening devices which extend into the interior of the exhaust vent. • Provide an opening with a free area of at least 25 square inches for introduction of outside air into the dryer room. • See the sections for electrical connection information. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

Installation Instructions
REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
MOBILE OR MANUFACTURED HOME
INSTALLATION
3
- Explosion Hazard
WARNING
Keep flammable materials and vapors, such as gasoline,
away from dryer.
Place dryer at least 18” (46 cm) above the floor for a
garage installation.
Failure to do so can result in death, explosion, or fire.
Installation must conform to the
MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24, PART 32–80 or
Standard CAN/CSA-Z240 MH, or, when such
standard is not applicable, with AMERICAN
NATIONAL STANDARD FOR MOBILE HOME,
ANSI/NFPA NO. 501B.
The dryer MUST be vented to the outdoors. The
exhaust vent must be securely fastened to a
non-combustible portion of the mobile home.
The vent MUST NOT be terminated beneath a
mobile or manufactured home.
The vent duct material MUST BE METAL.
KIT 14-D346-33 MUST be used to attach the dryer
securely to the structure.
The vent MUST NOT be connected to any other
duct, vent or chimney.
Do not use sheet metal screws or other
fastening devices which extend into the interior
of the exhaust vent.
Provide an opening with a free area of at least
25 square inches for introduction of outside air
into the dryer room.
See the sections for electrical connection
information.
If the dryer is approved for installation in an
alcove or closet, it will be stated on a label on the
dryer back.
The dryer MUST be vented to the outdoors. See
the EXHAUSTING THE DRYER section.
Minimum clearance between dryer cabinet and
adjacent walls or other surfaces is:
0” either side
3” front
3” rear
Minimum vertical space from dryer to overhead
shelves, cabinets, ceilings, etc., is 1” on top.
Consideration must be given to provide adequate
clearance for installation and service.
Closet doors must be louvered or otherwise
ventilated and have at least 60 square inches of
open area. If the closet contains both a washer
and a dryer, doors must contain a minimum of
120 square inches of open area.
NOTE:
WHEN THE EXHAUST DUCT IS LOCATED IN
THE REAR OF THE DRYER, THE CONFIGURATION OF
THE DUCTING MAY REQUIRE GREATER THAN 3” OF
REAR CLEARANCE.
MINIMUM CLEARANCE OTHER THAN
ALCOVE OR CLOSET INSTALLATION
Minimum clearance to combustible surfaces and
for air opening are: 0” both sides, 1” front and
3” rear. Consideration must be given to provide
adequate clearance for installation and service.