GE GUD27ESSJWW Installation Instructions - Page 6
Warning, Warning - canada
View all GE GUD27ESSJWW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Installation Instructions CONNECTING APPLIANCE USING 4-WIRE CONNECTION (MUST BE USED FOR MOBILE HOME INSTALLATION) (Cont.) &RQQHFWSRZHUFRUGDVIROORZV A. Connect the 2 hot lines to the outer screws of the WHUPLQDOEORFNPDUNHG/DQG/ %&RQQHFWWKHQHXWUDOZKLWH OLQHWRWKHFHQWHURIWKH WHUPLQDOEORFNPDUNHG1 7. Attach ground wire of power cord with the green ground VFUHZKROHDERYHVWUDLQUHOLHIEUDFNHW 7LJKWHQDOO WHUPLQDOEORFNVFUHZV VHFXUHO\ 8. Properly secure power cord to strain relief. 9. Reinstall the cover. WARNING: NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK. 3 EXHAUST INFORMATION EXHAUST INFORMATION (cont.) 24" DRYER EXHAUST LENGTH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Recommended Use only for short run installations 4" DIA. 4" DIA. 4" DIA. No. of 90º Elbows 0 1 2 4" Rigid Metal 43 Feet 33 Feet 24 Feet 2-1/2" Rigid Metal 36 Feet 26 Feet 16 Feet • For every additional 90° elbow, reduce the allowable vent V\VWHPOHQJWKE\IW • Two 45° elbows will be treated like one 90° elbow. For the side exhaust installations, add one 90° elbow to the chart. • The total vent system length includes all the straight portions DQGHOERZVRIWKHV\VWHPWUDQVLWLRQGXFWLQFOXGHG WARNING - IN CANADA AND IN THE UNITED STATES, THE REQUIRED EXHAUST DUCT DIAMETER IS 4 IN (102mm). DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE. 8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO • Increase the drying times and the energy cost. • Reduce the dryer life. $FFXPXODWHOLQW FUHDWLQJDSRWHQWLDO¿UHKD]DUG The correct exhaust installation is YOUR RESPONSIBILITY. Problems due to incorrect installation are not covered by the warranty. Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct. The MAXIMUM ALLOWABLE duct length and number of bends of the exhaust system depends upon the type of GXFWQXPEHURIWXUQVWKHW\SHRIH[KDXVWKRRGZDOOFDS and all conditions noted below. The maximum duct length for rigid metal duct is shown in the following table. 27" DRYER EXHAUST LENGTH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Recommended Use only for short run installations 4" DIA. 4" DIA. 4" DIA. No. of 90º Elbows 0 1 2 3 4" Rigid Metal 56 Feet 48 Feet 40 Feet 32 Feet 2-1/2" Rigid Metal 42 Feet 34 Feet 26 Feet 18 Feet EXHAUST SYSTEM CHECK LIST HOOD OR WALL CAP • Terminate in a manner to prevent back drafts or entry of birds or other wildlife. • Termination should present minimal resistance to WKH H[KDXVW DLU ÀRZ DQG VKRXOG UHTXLUH OLWWOH RU QR maintenance to prevent clogging. •Never install a screen in or over the exhaust duct. This could cause lint build up. :DOOFDSVPXVWEHLQVWDOOHGDWOHDVWLQDERYHJURXQG level or any other obstruction with the opening pointed down. SEPARATION OF TURNS For best performance, separate all turns by at least 4 ft. of straight duct, including distance between last turn and exhaust hood. TURNS OTHER THAN 90º • One turn of 45º or less may be ignored. • Two 45º turns should be treated as one 90º turn. • Each turn over 45º should be treated as one 90º turn. SEALING OF JOINTS • All joints should be tight to avoid leaks. The male end of each section of duct must point away from the dryer. • Do not assemble the ductwork with fasteners that extend into the duct. They will serve as a collection point for lint. 'XFW MRLQWV FDQ EH PDGH DLU DQG PRLVWXUHWLJKW E\ wrapping the overlapped joints with duct tape. +RUL]RQWDOUXQVVKRXOGVORSHGRZQWRZDUGWKHRXWGRRUV LQFKSHUIRRW INSULATION Duct work that runs through an unheated area or is near air conditioning should be insulated to reduce condensation DQGOLQWEXLOGXS