Adapting Microwave Blower for Outside Back Exhaust, NOTE: The blower unit exhaust
UPC - 084691078319
View all GE JVM3670WF manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
Installation Instructions B4. ADAPTING MICROWAVE BLOWER FOR OUTSIDE BACK EXHAUST 1 Remove and save screw that holds blower motor to microwave. Blower Motor Back of Microwave Blower Motor Screw 2 Carefully pull out the blower unit. The wires will extend far enough to allow you to adjust the blower unit. BEFORE: Fan Blade Openings Facing Up End B End A 3 Rotate blower unit counterclockwise 180°. Before Rotation After Rotation Back of Microwave Back of Microwave 4 Gently remove the wires from the grooves. Reroute the wires through grooves on other side of the blower unit. Before Rerouting After Rerouting 5 Roll the blower unit 90° so that fan blade openings are facing out the back of the microwave. Before Rolling After Rolling Back of Microwave Back of Microwave 6 Place the blower unit back into the opening. AFTER: Fan Blade Openings Facing Back End A End B CAUTION: Do not pull or stretch the blower unit wiring. Make sure the wires are not pinched. NOTE: The blower unit exhaust openings should match exhaust openings on rear of microwave oven. 7 Secure the blower unit to the microwave with the screw from Step 1. Blower Plate Back of Microwave Blower Motor Screw 8 Replace the blower plate in the same position as before with the screw. Wires Routed Through Right Side Wires Routed Through Left Side 17