GE NX-8 Installation Manual - Page 21
Location 37 - Siren And System Supervision - kit
UPC - 782136401462
View all GE NX-8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
L LOCATION 37 - SIREN AND SYSTEM SUPERVISION (5 segments, feature selection data) Location 37 is used to enable various system feature and reporting options. (Refer to the feature definitions.) Segment 1: 1 - On if siren sounds for "Telephone Line Cut" when armed. 2 - On if siren sounds for "Telephone Line Cut" when disarmed. 3 - On if siren blast at arming. 4 - On if siren blast at exit expiration. 5 - On if siren blast at closing kissoff. 6 - On if siren sounds during a "Cross Zone" verification time. 7 - On if siren sounds for a Zone or Box Tamper. 8 - On if siren blasts 1 time for keyswitch or wireless arming; 2 times for disarming. Segment 2: 1 - On if siren driver should be a voltage output. Off if on board siren driver enabled. 2 - On if siren sounds for expander trouble (required for UL installations). 3 - On for Immediate Restore by zone. Off for zones to restore only when siren is off. 4 - On if Dynamic Battery Test performed at arming. Off if performed at disarming. (See location 40) 5 - On if Battery Missing Test is performed every 12 seconds. 6 - On if Manual Bell Test performed during [r]-[4] test function. 7 - On if Manual Communicator Test performed during [r]- [4] test function. 8 - On if Box Tamper terminals on the control panel are enabled. Segment 3: 1 - On if Box Tamper report enabled. 2 - On if AC Fail reporting enabled. 3 - On if Low Battery reporting enabled. 4 - On if Aux. Power Overcurrent report enabled. 5 - On if Siren Supervision report enabled. 6 - On if Telephone Line Cut report enabled. 7 - On if Ground Fault Detection report enabled. 8 - On if Expander Trouble reporting enabled. Segment 4: 1 - On if Fail To Communicate report enabled. 2 - On if Log Full report enabled. 3 - On if Autotest report enabled. 4 - On if Start/End programming report enabled. 5 - On if End Download report enabled. 6 - On if Sensor Low Battery report enabled. 7 - On if Sensor Missing report enabled. 8 - Reserved. Segment 5: 1 = On enable Lost Clock service light. 2 = On enables Zone Doubling (requires NX-200 Zone Doubling Kit). 3 = On disables On-Board 8 zones. 4 = On will allow two trips on same cross-zone to activate an alarm. 5 = On will not allow zones that are force armed to report bypass. 6 = On enables Silent Exit option. 7 = Use internal crystal for clock. 8 = Disable Temporal Siren on Fire. NOTE: Do NOT disable for UL listed systems. L LOCATION 38 - SWINGER SHUTDOWN COUNT Location 38 contains the number of trips during an arming cycle that the NX8 will allow before bypassing a zone. The count determination is described in the feature definitions beginning on page 3. NOTE: For UL installations, this feature shall be disabled. . L LOCATION 39 - KEYPAD SOUNDER CONTROL (1 segment, feature selection data) Segment 1: 1 - On if keypad sounds for ATelephone Line Cut@ when the system is armed. 2 - On if keypad sounds for ATelephone Line Cut@ when disarmed. 3 - On if keypad sounds upon AC Power Failure. 4 - On if keypad sounds when a Low Battery is detected. 5 - On if keypad sounds during Cross Zone trip time. 6 - On if keypad sounds for zone and box tampers. 7 - Reserved. 8 - On if keypad sounds for expander trouble (required for UL installations). Page 21