GE NX-8 Installation Manual - Page 22

Note: If You Enable This Option, Verify That The Go To Program Code Is A Six - nx 8 code change

Page 22 highlights

L LOCATION 40 - SYSTEM TIMERS (10 segments, numerical data) Location 40 contains the duration of various system timing functions. Example: If you desire the duration of the Dynamic Battery Test to be 30 minutes, you should program [3]-[0]-[r] in segment 1 of this location. The [3]-[0] is the number of minutes, and the [r] stores the data and moves to the next segment of this location. Segment 1 - Dynamic Battery Test duration in minutes 0-255 minutes ("0" = no test) Segment 2 - AC Fail report delay in minutes 0-255 minutes. Segment 3 - Power Up Delay in seconds 0-60 seconds ("0" = no power up delay). Segment 4 - Siren Time in minutes 1-255 minutes. Segment 5 - Telephone Line Cut delay in seconds 0-255 seconds ("0" = no TLM). Segment 6 - Cross Zone time in minutes 0-255 ("0" = no cross zoning). Segment 7 - Chime time in 50 mS (1/20th second) increments from 0-12 seconds ("0" = follows zone 255 latched). Segment 8 - Dial delay in seconds 0-255 seconds ("0 " = no abort delay). Segment 9 - Fire Alarm Verification time in seconds 120-255 seconds ("0" = no fire alarm verification). NOTE: This feature is not approved for residential use in California Segment 10 -Listen-In time in seconds 0-255 ("0" = no Listen-In time). Note: The "Listen-In" feature cannot be enabled for UL Listed systems. The "Dynamic Battery Test" feature cannot exceed four (4) hours. The dial delay shall be set to -0-. LOCATION 41 - SPECIAL FEATURES (1 segment, feature selection data) Segment 1: 1 - On enables the 6-digit code option. If 6-digit option is enabled, all arm/disarm codes and the "Go To Program Code" are 6 digits. If this option is enabled, the default user 1 code is [1]-[2]-[3]-[4]-[5]-[6]. NOTE: IF YOU ENABLE THIS OPTION, VERIFY THAT THE "GO TO PROGRAM CODE" IS A SIXDIGIT CODE BEFORE EXITING PROGRAMMING. 2 - On requires code entry for [r]-[9]-[8] (perform call back download) and [r]-[9]-[9] (answer incoming call for download) functions. 3 - Enable Auto Cancel / Abort (Refer to feature definitions beginning on page 3) 4 - Enable Walk-Test Mode (Refer to feature definitions beginning on page 3) 5-8 Reserved. L LOCATION 42 - GO TO PROGRAM CODE (6 segments, numerical data) Location 42 contains the "Go To Program Code". This location contains either a 4 or 6-digit code. If the 6-digit code option is enabled in Location 41, THIS CODE MUST CONTAIN SIX (6) DIGITS. If this option is not enabled in location 41, the last 2 segments (digits) will be ignored. With the NX-8 disarmed, the "Go To Program Code" can be used to enter the Program Mode. LOCATION 43 - GO TO PROGRAM CODE PARTITION AND AUTHORIZATION (2 segments, feature selection) The "Go To Program Code" can be used as a standard arm/disarm code. When using the code to arm or disarm, the user ID is 255. (This code may not be changed in the Run Mode.) Segment 1: Segment 2: 1 - Reserved. 2 - On enables "Go To Program Code" as an arm only code. 3 - On enables "Go To Program Code" as an arm only after closing. 4 - On enables "Go To Program Code" as a master arm/disarm code (can change user codes) 5 - On enables "Go To Program Code" as an arm/disarm code. 6 - On enables "Go To Program Code" to bypass zones. 7 - On enables "Go To Program Code" opening and closing reports. 8 - Reserved. 1 - On enables the "Go To Program Code" for Partition #1. 2 - On enables the "Go To Program Code" for Partition #2. 3 - On enables the "Go To Program Code" for Partition #3. 4 - On enables the "Go To Program Code" for Partition #4. 5 - On enables the "Go To Program Code" for Partition #5. 6 - On enables the "Go To Program Code" for Partition #6. 7 - On enables the "Go To Program Code" for Partition #7. 8 - On enables the "Go To Program Code" for Partition #8. L LOCATION 44 - DURESS CODE (6 segments, numerical data) Page 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61

Page 22
L
LOCATION 40 - SYSTEM TIMERS
(10 segments, numerical data
)
Location 40 contains the duration of various system timing functions. Example: If you desire the duration of the
Dynamic Battery Test to be 30 minutes, you should program [3]-[0]-[
r
] in segment 1 of this location. The [3]-[0] is the
number of minutes, and the [
r
] stores the data and moves to the next segment of this location.
Segment 1
- Dynamic Battery Test duration in minutes 0-255 minutes
("0" = no test)
Segment 2
- AC Fail report delay in minutes 0-255 minutes.
Segment 3
- Power Up Delay in seconds 0-60 seconds ("0" = no power up delay).
Segment 4
- Siren Time in minutes 1-255 minutes.
Segment 5
- Telephone Line Cut delay in seconds 0-255 seconds
("0" = no TLM).
Segment 6
- Cross Zone time in minutes 0-255
("0" = no cross zoning).
Segment 7
- Chime time in 50 mS (1/20th second) increments from 0-12 seconds ("0" = follows zone 255 latched).
Segment 8
- Dial delay in seconds 0-255 seconds
(“0 ” = no abort delay).
Segment 9
- Fire Alarm Verification time in seconds 120-255 seconds
("0" = no fire alarm verification)
.
NOTE:
This feature is not approved for residential use in California
Segment 10
-Listen-In time in seconds 0-255
("0" = no Listen-In time).
Note: The "Listen-In" feature cannot be enabled for UL Listed systems. The "Dynamic Battery Test" feature
cannot exceed four (4) hours. The dial delay shall be set to -0-.
LOCATION 41 - SPECIAL FEATURES
(1 segment, feature selection data)
Segment 1:
1-
On enables the 6-digit code option. If 6-digit option is enabled, all arm/disarm codes and the "Go To
Program Code" are 6 digits.
If this option is enabled, the default user 1 code is [
1
]-[
2
]-[
3
]-[
4
]-[
5
]-[
6
].
NOTE: IF YOU ENABLE THIS OPTION, VERIFY THAT THE "GO TO PROGRAM CODE" IS A SIX-
DIGIT CODE BEFORE EXITING PROGRAMMING.
2-
On requires code entry for [
r
]-[
9
]-[
8
] (perform call back download) and [
r
]-[
9
]-[
9
] (answer incoming call for
download) functions.
3-
Enable Auto Cancel / Abort (Refer to feature definitions beginning on page 3)
4-
Enable Walk-Test Mode (Refer to feature definitions beginning on page 3)
5-8
Reserved.
L
LOCATION 42 - GO TO PROGRAM CODE (6 segments, numerical data)
Location 42 contains the "Go To Program Code". This location contains either a 4 or 6-digit code. If the 6-digit code
option is enabled in Location 41, THIS CODE MUST CONTAIN SIX (6) DIGITS.
If this option is not enabled in
location 41, the last 2 segments (digits) will be ignored. With the NX-8 disarmed, the "Go To Program Code" can be
used to enter the Program Mode.
LOCATION 43 - GO TO PROGRAM CODE PARTITION AND AUTHORIZATION (2 segments, feature selection)
The "Go To Program Code" can be used as a standard arm/disarm code. When using the code to arm or disarm, the
user ID is 255. (This code may not be changed in the Run Mode.)
Segment 1:
1 - Reserved.
2 - On enables "Go To Program Code" as an arm only code.
3 - On enables "Go To Program Code" as an arm only after closing.
4 - On enables "Go To Program Code" as a master arm/disarm code (can change user codes)
5 - On enables "Go To Program Code" as an arm/disarm code.
6 - On enables "Go To Program Code" to bypass zones.
7 - On enables "Go To Program Code" opening and closing reports.
8 - Reserved.
Segment 2:
1 - On enables the "Go To Program Code" for Partition #1.
2 - On enables the "Go To Program Code" for Partition #2.
3 - On enables the "Go To Program Code" for Partition #3.
4 - On enables the "Go To Program Code" for Partition #4.
5 - On enables the "Go To Program Code" for Partition #5.
6 - On enables the "Go To Program Code" for Partition #6.
7 - On enables the "Go To Program Code" for Partition #7.
8 - On enables the "Go To Program Code" for Partition #8.
L
LOCATION 44 - DURESS CODE (6 segments, numerical data)