GE PI6000 Installation Instructions - Page 4

Specifications, Product Ordering - pir

Page 4 highlights

Specifications Voltage Current Maximum loop rating Alarm output Alarm duration Cover tamper contacts Rating Operating temperature Humidity Pulse count RFI immunity Static Immunity Lightning immunity Detection range: PI6000 Pet Immune 6000 High Density Mounting Dimensions: Width Depth Height Color 10 to 16VDC 14mA Typical 20mA max. 16 VDC, 50mA Fail safe contacts-closed loop Normally Closed (N.C.) 5 seconds ( ± 0.5 sec.) Closed loop 16V, 50mA 14°F to 122°F (-10°C to 50°C) 5 to 95% non-condensing Two-pulse or three-pulse Greater than 10V/meter from 10 to 1000MHz 20 kV 2.4 kV, 1.2 joules max. energy impulse, 100 usec duration on field wiring 40' (12.2m) x 90° 35' (10.1m) x 90° Flat wall or corner 3.05" (7.75cm) 1.90" (4.83cm) 2.68" (6.81cm) White The unit should be connected to a UL Listed power supply or control unit capable of providing a minimum of 4 hours standby power. The equipment should be installed in accordance with NFPA 70. The unit should be tested at least once a year. 2.68" 6.81cm Front View Side View 3.05" 7.75cm Figure 7. Dimensions 1.90" 4.83cm Product Ordering Model PI6000 6000 Description 40' x 40' PIR with 30 lb Pet Immune Lens, closed loop, with tamper 35' x 35' PIR with High Density Lens, closed loop, with tamper Listing C-UL US C-UL US g GE Security 12345 SW Leveton Drive Tualatin, OR 97062 Phone: 503-692-4052 USA & Canada: 800-547-2556 Technical Service: 800-648-7424 FaxBack: 800-483-2495 wm 15480D / October, 2004 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

  • 1
  • 2
  • 3
  • 4

15480D / October, 2004
Specifications
Voltage
10 to 16VDC
Current
14mA Typical 20mA max.
Maximum loop rating
16 VDC, 50mA
Alarm output
Fail safe contacts-closed loop
Normally Closed (N.C.)
Alarm duration
5 seconds (
±
0.5 sec.)
Cover tamper contacts
Closed loop
Rating
16V, 50mA
Operating temperature
14°F to 122°F (-10°C to 50°C)
Humidity
5 to 95%
non-condensing
Pulse count
Two-pulse or three-pulse
RFI immunity
Greater than 10V/meter from 10 to
1000MHz
Static Immunity
20 kV
Lightning immunity
2.4 kV, 1.2 joules max. energy
impulse, 100 usec duration on field
wiring
Detection range:
PI6000 Pet Immune
40’ (12.2m) x 90°
6000 High Density
35’ (10.1m)
x 90°
Mounting
Flat wall or corner
Dimensions:
Width
3.05" (7.75cm)
Depth
1.90" (4.83cm)
Height
2.68" (6.81cm)
Color
White
USA & Canada: 800-547-2556
Technical Service: 800-648-7424
FaxBack: 800-483-2495
wm
GE Security
12345 SW Leveton Drive
Tualatin, OR 97062
Phone: 503-692-4052
Figure 7.
Dimensions
Front View
Side View
2.68”
6.81cm
3.05”
7.75cm
1.90”
4.83cm
The unit should be connected to a UL Listed power supply or control unit
capable of providing a minimum of 4 hours standby power.
The equipment should be installed in accordance with NFPA 70.
The unit should be tested at least once a year.
Model
Description
Listing
PI6000
40’ x 40’ PIR with 30 lb Pet Immune Lens, closed loop, with tamper
C-UL US
6000
35’ x 35’ PIR with High Density Lens, closed loop, with tamper
C-UL US
Product Ordering
g