PP989DN GE Profile™ 30" Downdraft Electric Cooktop Dimensions and Installation Information Installing the Ductwork: Use galvanized or aluminum duct in 6" round or 3-1/4" x 10" size, or combination of both. PVC duct or locally approved piping should be used if installing under a poured concrete slab. Local building code must be followed in specifying type and schedule of all duct used. Note: Ductwork must be vented to outside. Do not vent into a wall, ceiling, crawlspace, attic or any concealed space. Always use an appropriate roof or wall cap with damper. Laundry-type wall caps should never be used. For maximum efficiency use the shortest and straightest duct run possible, with as few fittings as possible. For satisfactory performance the duct run should not exceed 100 feet equivalent length. Refer to the table of equivalent lengths (shown in installation instructions) for various duct configurations. Through Cabinet Toe Space 10-1/8 Between Floor Joist 6-1/8 Venting Options Inside Wall to Roof Direct to Outside 9-1/8 18-3/4 For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000. Downward Venting Rear Wall Venting Dimension and installation information are shown in inches. Listed by Underwriters Laboratories Specification Created 7/08 220977

  • 1
  • 2
  • 3

Dimensions and Installation Information
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
Dimension and installation information are shown in inches.
Listed by
Underwriters
Laboratories
PP989DN
GE Profile
30" Downdraft Electric Cooktop
Specification Created 7/08
220977
Installing the Ductwork:
Use galvanized
or aluminum duct in 6” round or 3-1/4” x
10” size, or combination of both.
PVC duct
or locally approved piping should be used
if installing under a poured concrete slab.
Local building code must be followed in
specifying type and schedule of all duct used.
Note:
Ductwork must be vented to outside.
Do not vent into a wall, ceiling, crawlspace,
attic or any concealed space. Always use
an appropriate roof or wall cap with damper.
Laundry-type wall caps should never
be used.
For maximum efficiency use the
shortest and straightest duct run possible,
with as few fittings as possible.
For satisfactory
performance the duct run
should not exceed 100 feet equivalent length.
Refer to the table of equivalent lengths
(shown in installation instructions) for
various duct configurations.
Rear Wall Venting
Downward Venting
Through Cabinet Toe Space
Inside Wall to Roof
Direct to Outside
Between Floor Joist
9-1/8
10-1/8
18-3/4
6-1/8