GE RAK65A1 Literature - Page 11
RAK204, Standard Sub-Base, RAK205CW, Chaseway, RAK5157/5207/5307, 277-Volt Universal Power Supply
![]() |
View all GE RAK65A1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Zoneline units Chaseway Power cord and junction box not included with sub-base. Chaseway RAK204 (AZ Series*-2200, 2500, 3200 and 3500 only) Standard Sub-Base The RAK204 sub-base is made of heavy-gauge steel to provide support of the wall case. It has full base enclosure with break-away side channels, simple connection to wall case, and 4-point leveling legs. The sub-base will adapt to service conduit, circuit breakers and receptacles up to 30 amps. It may also be used as a non-electrical sub-base to provide support for the unit. Kit No. Sub-Base Circuit Ampacity Chaseway Power Cord RAK204U** Standard N/A Not Included Not Included RAK204D20 Sub-Base 230/208V 15 & 20 Included Not Included RAK204D30 Sub-Base 230/208V 30 Included Not Included RAK204E15 Sub-Base 265/277V 15 Included Not Included RAK204E20 Sub-Base 265/277V 20 Included Not Included RAK204E30 Sub-Base 265/277V 30 Included Not Included RAK204 (AZ Series*-2800, 3800, 5200, 5500 and 5800 only) Standard Sub-Base The RAK204 sub-base is made of heavy-gauge steel to provide support of the wall case. It has full base enclosure with break-away side channels, simple connection to wall case, and 4-point leveling legs. The sub-base will adapt to service conduit, circuit breakers and receptacles up to 30 amps. It may also be used as a non-electrical sub-base to provide support for the unit. Kit No. Sub-Base Circuit Ampacity Chaseway Power Cord RAK204D15P Sub-Base 230/208V 15 Included Included RAK204D20P Sub-Base 230/208V 20 Included Included RAK204D30P Sub-Base 230/208V 30 Included Included RAK205CW (AZ Series*-2200, 2500, 2800, 3200, 3500, 3800, 5200, 5500 and 5800 only) Chaseway Chaseway for wiring containment between junction box on chassis and RAK204U sub-base. RAK5157/5207/5307† (AZ Series*-2800, 3800, 5500 & 5800 only) 265/277-Volt Universal Power Supply Kit • 9-pin connector with three 7" 12-gauge conductor wires. Circuit Kit No. Volts Heater Wattage Ampacity RAK5157 265/277 2.55 kw 15 RAK5207 265/277 3.45 kw 20 RAK5307 265/277 5.00 kw 30 *A-B Series: Zonelines built before 1987 - Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 - includes AZR Series - Zoneline 1000, 2000, 2500, 2700, 3000, 4000, 5000; AZ Series: Zonelines built after 1992 - Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800/3800/5800. **RAK204U May be used with AZC and AZ 2100, 3100, 2600 and 5100. †The power connection kit determines the heater wattage and current requirements when it is plugged into the Zoneline unit. NOTE: All power cord kits and permanent connection kits may be used on all units (of matching voltage). NOTE: 7,000 BTU models do not have 5,000 watt heaters. 11
![](/manual_guide/products/general-electric-rak65a1-literature-ed2c9e0/11.png)