GE RAK65A1 Literature - Page 21

Thermostats-Electric Resistance Heat

Page 21 highlights

Thermostats-Electric Resistance Heat RAK163A1 (A-B, AZ, and AZR Series*) Cooling with Electric Heat Remote Thermostat RAK163A1 is used with resistance heat models. Units have integral low-voltage terminal board to connect with thermostat. Temperature, operation mode, and fan operation are controlled at wall-mounted thermostat. Note: 2200 series requires RAKOIM. RAK364T1-Wall-Mounted Thermostat (transmitter) (AZ2500, 2800, and 7500 series*) Electric Heat Wireless Programmable Remote Thermostat RAK364R1-Chassis-Mounted Receiver (AZ2500, 2800, and 7500 series*) Electric Heat Wireless Programmable Remote Receiver • P rogrammable wireless remote thermostat with Single-Stage Cooling and Single-Stage Heating for electric (resistance) heat models. • Programmable for 7-day programs. • Battery-operated transmitter uses standard AA batteries. • Receiver is mounted on chassis and wired to low-voltage terminals. RAK164D1 (A-B, AZ, 2500, 2800, 7500 and AZR Series*) Cooling with Electric Heat Digital Remote Thermostat • 24V AC digital remote wall thermostat with Single-Stage Cooling and Single-Stage Heating for resistance heat models. • Requires 5-wire hook-up. RAK164P1 (A-B, AZ, 2500, 2800, 7500 and AZR Series*) Cooling with Electric Heat Programmable Remote Thermostat • 24V AC programmable remote wall thermostat with Single-Stage Cooling and Single-Stage Heating for resistance heat models. • Programmable for 7-day or 5+2-day programs. • Requires 5-wire hook-up. *A-B Series: Zonelines built before 1987 - Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 - includes AZR Series - Zoneline 1000, 2000, 2500, 2700, 3000, 4000, 5000; AZ Series: Zonelines built after 1992 - Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500, Zoneline 2800, 3800, 5800. 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

21
RAK163A1
(A-B, AZ, and AZR Series*)
Cooling with Electric Heat Remote Thermostat
RAK16±A1 is used with resistance heat models. Units have
integral low-voltage terminal board to connect with thermostat.
Temperature, operation mode, and fan operation are controlled
at wall-mounted thermostat.
Note:
2200 series requires RAKOIM.
Thermostats—Electric Resistance Heat
*
A-B Series:
Zonelines built before 1987 – Zoneline
I, II, III,
and
IV; AZC Series:
Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, ±000,
4000, 5000;
AZ Series:
Zonelines built after 1992 – Zoneline 2100, ±100, 2600, 5100 / Zoneline 2200, ±200, 5200 / Zoneline 2500, ±500, 5500, Zoneline 2800, ±800, 5800.
RAK164P1
(A-B, AZ, 2500, 2800, 7500 and AZR Series*)
Cooling with Electric Heat Programmable Remote Thermostat
24V AC programmable remote wall thermostat with Single-Stage
Cooling and Single-Stage Heating for resistance heat models.
• Programmable for 7-day or 5+2-day programs.
• Requires 5-wire hook-up.
RAK164D1
(A-B, AZ, 2500, 2800, 7500 and AZR Series*)
Cooling with Electric Heat Digital Remote Thermostat
24V AC digital remote wall thermostat with Single-Stage
Cooling and Single-Stage Heating for resistance heat models.
• Requires 5-wire hook-up.
RAK364T1—Wall-Mounted Thermostat (transmitter)
(AZ2500, 2800, and 7500 series*)
Electric Heat Wireless Programmable Remote Thermostat
RAK364R1—Chassis-Mounted Receiver
(AZ2500, 2800, and 7500 series*)
Electric Heat Wireless Programmable Remote Receiver
Programmable wireless remote thermostat with Single-Stage Cooling
and Single-Stage Heating for electric (resistance) heat models.
• Programmable for 7-day programs.
• Battery-operated transmitter uses standard AA batteries.
• Receiver is mounted on chassis and wired to low-voltage terminals.