Genie ReliaG 600 Owner's Manual - Page 18

Caution

Page 18 highlights

3b. Wiring (pre-wired). ‡ Route wire from wall to Safe-T-Beam® sensors (Fig. 4-5b). ‡ Splice pre-wiring to shortened sensor wire, match wire pairs dash-to-dash and plain-to-plain. - Trim sensor wire to approximately one foot (1 ft) from sensor. - Split and strip ends of sensor wires and pre-wired wires (Fig. 4-7). - Splice wires together with (provided) wire nuts. ‡ Route wire from ceiling to power head Wire Nut (Fig. 4-5b). ‡ Securely fasten wires where they exit wall and ceiling as you go. - Use insulated staples. - Staples should be snug only. Insulated Staple Wall Red Source Wall Green Sensor Ceiling 6 5 4 3 2 1 or 6 5 4 3 2 1 Power Head Dashed Line = striped wire Solid Line = white wire FIG. 4-5b Pre-Wired source and sensor wiring methods. Insert Wire Wire Into Connector Wire CAUTION Staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the Safe-T-Beam® System to stop working. When using the insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly. Use this wire routing if NOT pre-wired 4. Split and strip ends of sensor wires (Fig. 4-7). NOTE: For rear cover locate Box 4. 5. Attach Safe-T-Beam® wire to power head wire terminal. ‡ Route Safe-T-Beam® wires through wire guide. - Insert wire into terminal holes and lightly press in the orange locking clips above each terminal hole. (You can use a pencil or small screwdriver to comfortably reach in and lightly press down locking clips.) Insert white wires to 'even' numbered terminal holes and striped wires into 'odd' terminal holes (Fig. 4-5b). Locking Clips Terminal Holes 65 432 1 Invisible Light Beam Source or Sensor Protection Area FIG. 4-6 Wire routing. Source or Sensor 2" Dashed Line = striped wire 1/2" FIG. 4-7 Splitting and stripping FIG. 4-8 . Insert wires 654 321 +- PB Infrared Sensor Solid Line = white wire - Confirm wire lock by lightly tugging on the wire. The wire should remain in the terminal hole. ‡ Install rear cover. The rear cover is the same color as the power head clips and body (Fig. 4-9). ‡ Do not install the white (lamp) cover at this time. NOTE: Safe-T-Beam® alignment check must be performed following connection to electrical power (see page 19). DO NOT PLUG IN YET! (Power Head With Rear Cover Removed) Cover clips FIG. 4-9 Install rear cover. 18 PN# 3642036534, 02/26/2010 REV. 1 .

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

PN# 3642036534, 02/26/2010
REV. 1
18
3b.
Wiring (pre-wired)
.
±
Route wire from wall to Safe-T-Beam
®
sensors
(Fig. 4-5b)
.
±
Splice pre-wiring to shortened sensor wire,
match wire pairs
dash-to-dash
and
plain-to-plain
.
- Trim sensor wire to approximately one foot
(1 ft) from sensor.
- Split and strip ends of sensor wires and
pre-wired wires
(Fig. 4-7).
- Splice wires together with (provided)
wire nuts.
±
Route wire from ceiling to power head
(Fig. 4-5b)
.
±
Securely fasten wires where they exit
wall and ceiling as you go.
– Use insulated staples.
– Staples should be snug only.
4.
Split and strip ends of sensor wires (Fig. 4-7)
.
NOTE: For rear cover locate Box 4.
5.
Attach Safe-T-Beam
®
wire to power head wire
terminal.
±
Route Safe-T-Beam
®
wires through wire guide.
– Insert wire into terminal holes and lightly press
in the orange locking clips above each terminal
hole. (You can use a pencil or small
screwdriver to comfortably reach in and lightly
press down locking clips.) Insert white wires to
'even' numbered terminal holes and striped
wires into 'odd' terminal holes
(Fig. 4-5b).
– Confirm wire lock by lightly tugging on the wire.
The wire should remain in the terminal hole.
±
Install rear cover. The rear cover is the same
color as the power head clips and body
(Fig. 4-9).
±
Do not install the white (lamp) cover at this time.
NOTE: Safe-T-Beam
®
alignment check must be
performed following connection to electrical
power (see page 19). DO NOT PLUG IN YET!
Staples which are too tight can cut or pinch wires.
Cut or pinched wires can cause the Safe-T-Beam
®
System to stop working. When using the insulated
staples, make sure you fasten them only as tightly
as needed to hold the wire snugly.
CAUTION
FIG. 4-7
Splitting
and stripping
.
FIG. 4-6
Wire routing
.
Wire
Wire
Source or Sensor
Invisible Light Beam
Protection Area
Insert Wire
Into Connector
Use this
wire routing
if NOT pre-wired
1
2
3
4
Terminal
Holes
Locking
Clips
5
6
+–
P
B
InfraredSensor
1
2
3
4
5
6
FIG. 4-8
Insert wires
.
(Power Head With Rear Cover Removed)
FIG. 4-5b Pre-Wired source and sensor wiring
methods
.
or
6
5
4
3
2
1
6
5
4
3
2
1
Sensor
Source
n
e
e
r
G
d
e
R
Power
Head
Dashed Line = striped wire
Solid Line = white wire
Dashed Line = striped wire
Solid Line
= white wire
Wall
Wall
Ceiling
1/2"
2"
Cover clips
FIG. 4-9
Install rear cover
.
Insulated
Staple
Wire Nut
Source or Sensor