Gigabyte A520M H User Manual - Page 31

Fan Control Use Temperature Input, Temperature Interval, Fan Control Mode, Fan Stop, Temperature

Page 31 highlights

&& Fan Control Use Temperature Input Allows you to select the reference temperature for fan speed control. && Temperature Interval Allows you to select the temperature interval for fan speed change. && Fan Control Mode Auto Lets the BIOS automatically detect the type of fan installed and sets the optimal control mode. (Default) Voltage Voltage mode is recommended for a 3-pin fan. PWM PWM mode is recommended for a 4-pin fan. && Fan Stop Enables or disables the fan stop function. You can set the temperature limit using the temperature curve. The fan stops operation when the temperature is lower than the limit. (Default: Disabled) && Temperature Displays the current temperature of the selected target area. && Fan Speed Displays current fan speeds. && Temperature Warning Sets the warning threshold for temperature. When temperature exceeds the threshold, BIOS will emit warning sound. Options are: Disabled (default), 60oC/140oF, 70oC/158oF, 80oC/176oF, 90oC/194oF. && Fan Fail Warning Allows the system to emit warning sound if the fan is not connected or fails. Check the fan condition or fan connection when this occurs. (Default: Disabled) - 31 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41

&
Fan Control Use Temperature Input
Allows you to select the reference temperature for fan speed control.
&
Temperature Interval
Allows you to select the temperature interval for fan speed change.
&
Fan Control Mode
±
Auto
Lets the BIOS automatically detect the type of fan installed and sets the optimal control
mode. (Default)
±
Voltage
Voltage mode is recommended for a 3-pin fan.
±
PWM
PWM mode is recommended for a 4-pin fan.
&
Fan Stop
Enables or disables the fan stop function. You can set the temperature limit using the temperature curve.
The fan stops operation when the temperature is lower than the limit. (Default: Disabled)
&
Temperature
Displays the current temperature of the selected target area.
&
Fan Speed
Displays current fan speeds.
&
Temperature Warning
Sets the warning threshold for temperature. When temperature exceeds the threshold, BIOS will emit
warning sound. Options are: Disabled (default), 60
o
C/140
o
F, 70
o
C/158
o
F, 80
o
C/176
o
F, 90
o
C/194
o
F.
&
Fan Fail Warning
Allows the system to emit warning sound if the fan is not connected or fails. Check the fan condition or fan
connection when this occurs. (Default: Disabled)
- 31 -