BIOS Setup • SDRAM Timing Configuration Auto Manual Set SDRAM Timing Configuration to Auto. ( Default value ) Set SDRAM Timing Configuration to Manual. • SDRAM Trc Timing Value This function specify the minimum time from activate to activate of the same bank. 3 Cycle 4 Cycle 5 Cycle 6 Cycle 7 Cycle 8 Cycle Set SDRAM Trc Timing Value to 3 Cycle. Set SDRAM Trc Timing Value to 4 Cycle. Set SDRAM Trc Timing Value to 5 Cycle. Set SDRAM Trc Timing Value to 6 Cycle. Set SDRAM Trc Timing Value to 7 Cycle. Set SDRAM Trc Timing Value to 8 Cycle. ( Default value ) • SDRAM Trp Timing Value This function specify the delay from precharge command to activate command. 3 Cycle 2 Cycle Set SDRAM Trp Timing Value to 3 Cycle. ( Default value ) Set SDRAM Trp Timing Value to 2 Cycle. • SDRAM Tras Timing Value This function specify the minimum bank (SRAS[2:0]#) active time. 2 Cycle 3 Cycle 4 Cycle 5 Cycle 6 Cycle 7 Cycle Set SDRAM Tras Timing Value to 2 Cycle. Set SDRAM Tras Timing Value to 3 Cycle. Set SDRAM Tras Timing Value to 4 Cycle. Set SDRAM Tras Timing Value to 5 Cycle. ( Default value ) Set SDRAM Tras Timing Value to 6 Cycle. Set SDRAM Tras Timing Value to 7 Cycle. • SDRAM CAS Latency This function specify the delay from SCAS[2:0]# to data valid. 2 Cycle 3 Cycle Set SDRAM CAS Latency to 2 Cycle. Set SDRAM CAS Latency to 3 Cycle. ( Default value ) 36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

BIOS Setup
36
SDRAM Timing Configuration
Auto
Set SDRAM Timing Configuration to Auto.
( Default value )
Manual
Set SDRAM Timing Configuration to Manual.
SDRAM Trc Timing Value
This function specify the minimum time from activate to activate of the same bank.
3 Cycle
Set SDRAM Trc Timing Value to 3 Cycle.
4 Cycle
Set SDRAM Trc Timing Value to 4 Cycle.
5 Cycle
Set SDRAM Trc Timing Value to 5 Cycle.
6 Cycle
Set SDRAM Trc Timing Value to 6 Cycle.
7 Cycle
Set SDRAM Trc Timing Value to 7 Cycle.
8 Cycle
Set SDRAM Trc Timing Value to 8 Cycle.
( Default value )
SDRAM Trp Timing Value
This function specify the delay from precharge
command to activate command.
3 Cycle
Set SDRAM Trp Timing Value to 3 Cycle.
( Default value )
2 Cycle
Set SDRAM Trp Timing Value to 2 Cycle.
SDRAM Tras Timing Value
This function specify the minimum bank (SRAS[2:0]#) active time.
2 Cycle
Set SDRAM Tras Timing Value to 2 Cycle.
3 Cycle
Set SDRAM Tras Timing Value to 3 Cycle.
4 Cycle
Set SDRAM Tras Timing Value to 4 Cycle.
5 Cycle
Set SDRAM Tras Timing Value to 5 Cycle.
( Default value )
6 Cycle
Set SDRAM Tras Timing Value to 6 Cycle.
7 Cycle
Set SDRAM Tras Timing Value to 7 Cycle.
SDRAM CAS Latency
This function specify the delay from SCAS[2:0]# to data valid.
2 Cycle
Set SDRAM CAS Latency to 2 Cycle.
3 Cycle
Set SDRAM CAS Latency to 3 Cycle.
( Default value )