Gigabyte GA-7PESVL Manual - Page 23

SATA0/SATA1 SATA 6Gb/s Connectors/SATA1 Supports SATA DOM Function, SATA2/SATA3/SATA4/SATA5 SATA 3Gb

Page 23 highlights

11) SATA0/SATA1 (SATA 6Gb/s Connectors/SATA1 Supports SATA DOM Function) The SATA connectors conform to SATA 6Gb/s standard and are compatible with SATA 3Gb/s and 1.5Gb/s standard. Each SATA connector supports a single SATA device. The SATA1 connector supports SATA DOM function. Normal Mode: SATA0 SATA1 Pin No. Definition 1 GND 2 TXP 7 3 TXN 4 GND 5 RXN 6 RXP 7 GND 1 SATA DOM Mode: Pin No. Definition 1 GND 2 TXP 3 TXN 4 GND 5 RXN 6 RXP 7 P5V DEBUG PORT • A RAID 0 or RAID 1 configuration requires at least two hard drives. If more than two hard drives are configured, the total number of hard drives must be an even number. • A RAID 10 configuration requires four hard drives. (Note) When a RAID configuration is built across the SATA 6Gb/s channels, the system performance of the RAID configuration may vary depends on the devices are connected. 12) SATA2/SATA3/SATA4/SATA5 (SATA 3Gb/s Connectors) The SATA connectors conform to SATA 3Gb/s standard and are compatible with SATA 1.5Gb/s standard. Each SATA connector supports a single SATA device. SATA4 SATA2 SATA5 SATA3 Pin No. Definition 7 1 GND 2 TXP 3 TXN 4 GND 5 RXN 1 6 RXP 7 GND Hardware Installation - 23 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91

Hardware Installation
- 23 -
Pin No.
Definition
1
GND
2
TXP
3
TXN
4
GND
5
RXN
6
RXP
7
GND
Pin No.
Definition
1
GND
2
TXP
3
TXN
4
GND
5
RXN
6
RXP
7
GND
Pin No.
Definition
1
GND
2
TXP
3
TXN
4
GND
5
RXN
6
RXP
7
P5V
A RAID 0 or RAID 1 configuration requires at least two hard drives. If more than two hard drives
are configured, the total number of hard drives must be an even number.
A RAID 10 configuration requires four hard drives.
7
7
1
1
(Note)
When a RAID configuration is built across the SATA 6Gb/s channels, the system performance of
the RAID configuration may vary depends on the devices are connected.
11) SATA0/SATA1 (SATA 6Gb/s Connectors/SATA1 Supports SATA DOM Function)
The SATA connectors conform to SATA 6Gb/s standard and are compatible with SATA 3Gb/s and
1.5Gb/s standard. Each SATA connector supports a single SATA device.
The SATA1 connector supports SATA DOM function.
Normal Mode
:
SATA DOM Mode
:
SATA2
SATA4
SATA3
SATA5
12) SATA2/SATA3/SATA4/SATA5 (SATA 3Gb/s Connectors)
The SATA connectors conform to SATA 3Gb/s standard and are compatible with SATA 1.5Gb/s standard.
Each SATA connector supports a single SATA device.
SATA0
SATA1