Gigabyte GA-H81M-S2PV User Manual - Page 21

CPU/System Fan Fail Warning, CPU Fan Speed Control

Page 21 highlights

&& CPU/System Temperature Displays current CPU/system temperature. && CPU/System Fan Speed Displays current CPU/system fan speeds. && CPU/System Temperature Warning Sets the warning threshold for CPU/system temperature. When CPU/system temperature exceeds the threshold, BIOS will emit warning sound. Options are: Disabled (default), 60oC/140oF, 70oC/158oF, 80oC/176oF, 90oC/194oF. && CPU/System Fan Fail Warning Allows the system to emit warning sound if the fan is not connected or fails. Check the fan condition or fan connection when this occurs. (Default: Disabled) && CPU Fan Speed Control Allows you to determine whether to enable the fan speed control function and adjust the fan speed. Normal Allows the fan to run at different speeds according to the CPU temperature. You can adjust the fan speed with System Information Viewer based on your system requirements. (Default) Silent Allows the fan to run at slow speeds. Manual Allows you to control the fan speed under the Fan Speed Percentage item. Full Speed Allows the fan to run at full speeds. && Fan Speed Percentage Allows you to control the fan speed. This item is configurable only when CPU Fan Speed Control is set to Manual. Options are: 0.75 PWM value /oC ~ 2.50 PWM value /oC. && System Fan Speed Control Allows you to determine whether to enable the fan speed control function and adjust the fan speed. Normal Allows the fan to run at different speeds according to the system temperature. You can adjust the fan speed with System Information Viewer based on your system requirements. (Default) Silent Allows the fan to run at slow speeds. Manual Allows you to control the fan speed under the Fan Speed Percentage item. Full Speed Allows the fan to run at full speeds. && Fan Speed Percentage Allows you to control the fan speed. This item is configurable only when System Fan Speed Control is set to Manual. Options are: 0.75 PWM value /oC ~ 2.50 PWM value /oC. `` Miscellaneous Settings && PCIe Slot Configuration Allows you to set the operation mode of the PCI Express slots to Gen 1 or Gen 2. Actual operation mode is subject to the hardware specification of each slot. Auto lets the BIOS automatically configure this setting. (Default: Auto) && 3DMark01 Boost Allows you to determine whether to enhance some legacy benchmark performance. (Default: Disabled) - 21 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

- 21 -
&
CPU/System Temperature
Displays current CPU/system temperature.
&
CPU/System Fan Speed
Displays current CPU/system fan speeds.
&
CPU/System Temperature Warning
Sets the warning threshold for CPU/system temperature. When CPU/system temperature exceeds
the threshold, BIOS will emit warning sound. Options are: Disabled (default), 60
o
C/140
o
F, 70
o
C/158
o
F,
80
o
C/176
o
F, 90
o
C/194
o
F.
&
CPU/System Fan Fail Warning
Allows the system to emit warning sound if the fan is not connected or fails. Check the fan condition or fan
connection when this occurs. (Default: Disabled)
&
CPU Fan Speed Control
Allows you to determine whether to enable the fan speed control function and adjust the fan speed.
±
Normal
Allows the fan to run at different speeds according to the CPU temperature. You
can adjust the fan speed with System Information Viewer based on your system
requirements. (Default)
±
Silent
Allows the fan to run at slow speeds.
±
Manual
Allows you to control the fan speed under the
Fan Speed Percentage
item.
±
Full Speed
Allows the fan to run at full speeds.
&
Fan Speed Percentage
Allows you to control the fan speed. This item is configurable only when
CPU Fan Speed Control
is set
to
Manual
. Options are: 0.75 PWM value /
o
C ~ 2.50 PWM value /
o
C.
&
System Fan Speed Control
Allows you to determine whether to enable the fan speed control function and adjust the fan speed.
±
Normal
Allows the fan to run at different speeds according to the system temperature. You
can adjust the fan speed with System Information Viewer based on your system
requirements. (Default)
±
Silent
Allows the fan to run at slow speeds.
±
Manual
Allows you to control the fan speed under the
Fan Speed Percentage
item.
±
Full Speed
Allows the fan to run at full speeds.
&
Fan Speed Percentage
Allows you to control the fan speed. This item is configurable only when
System Fan Speed Control
is
set to
Manual
. Options are: 0.75 PWM value /
o
C ~ 2.50 PWM value /
o
C.
`
Miscellaneous Settings
&
PCIe Slot Configuration
Allows you to set the operation mode of the PCI Express slots to Gen 1 or Gen 2. Actual operation mode is
subject to the hardware specification of each slot.
Auto
lets the BIOS automatically configure this setting.
(Default: Auto)
&
3DMark01 Boost
Allows you to determine whether to enhance some legacy benchmark performance. (Default: Disabled)