Installation Procedure For: AU142AEEAA, AU182AEEAA To Indoor Unit Electric wiring OUTDOOR UNIT 1 2 3 TERMINAL BLOCK Y/G FIG.1 For :, AU242AGEAA, AU282AHEAA To Indoor Unit Y/G L N 12 3 POWER SUPPLY: 1PH, 220-230V~, 50Hz OUTDOOR UNIT TERMINAL BLOCK FIG.2 For:AU28NAHEAA, AU36NAIEAA, AU48NAIEAA, AU52NAIEAA, AU60NAIEAA To Indoor Unit R S TN 1 2 3 Y/G OUTDOOR UNIT TERMINAL BLOCK POWER SUPPLY: 380-400V, 3N~, 50Hz FIG.3 WARNING DO NOT CONNECT THE NEUTRAL WIRE N TO R , S OR T PHASE. INTERCONNECTING WIRES MUST BE WIRED ACCORDING TO FIG.1 FIG.2 FIG.3.INCORRECT WIRING CAUSE EQUIPMENT DAMAGE. (3) Wiring procedure 1) Remove set screws on the side before taking off the front panel toward the direction shown in figure. 2) Connect wires to the terminal block correctly and fix the wires with a wire clamp equipped nearby the terminal block. 3) Route the wires in a proper way and penetrate the wires through the opening for electric wiring on the side panel. 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

Electric wiring
12
(3)
Wiring procedure
1) Remove set screws on the side before taking off the front panel toward
the direction shown in figure.
2) Connect wires to the terminal block correctly and fix the wires with a
wire clamp equipped nearby the terminal block.
3) Route the wires in a proper way and penetrate the wires through the
opening for electric wiring on the side panel.
WARNING
DO NOT CONNECT THE NEUTRAL WIRE
TO
,
OR
PHASE.
INTERCONNECTING WIRES MUST BE WIRED ACCORDING TO FIG.1
FIG.2 FIG.3.INCORRECT WIRING CAUSE EQUIPMENT DAMAGE.
N
R
S
T
Installation Procedure
For: AU142AEEAA, AU182AEEAA
OUTDOOR UNIT
TERMINAL BLOCK
1 2 3
FIG.1
To Indoor Unit
Y/G
FIG.2
For :, AU242AGEAA, AU282AHEAA
1PH, 220-230V~, 50Hz
POWER SUPPLY:
OUTDOOR UNIT
TERMINAL BLOCK
L N
1 2
3
Y/G
To Indoor Unit
FIG.3
For:AU28NAHEAA, AU36NAIEAA, AU48NAIEAA, AU52NAIEAA, AU60NAIEAA
OUTDOOR UNIT
TERMINAL BLOCK
POWER SUPPLY:
380-400V, 3N~, 50Hz
N 1 2 3
Y/G
To Indoor Unit
R S T