Haier AU222XFERA User Manual - Page 9

Limitations on the installation

Page 9 highlights

Limitations on the installation 3. Limitations values on the piping work . L1 A h L2 B H + H L3 C The piping length information, please refer the following table. Item Unit Descriptions A, B, Cliquid pipe mm Size of the liquid side connection pipe A, B, C Gas pipe mm Size of the gas side connection pipe L1 (one way) L2 (one way) m Pipe length when the compressor connects with two indoor units m Pipe length when the compressor connects with two indoor units L3 (one way) m Pipe length when the compressor connects only one indoor unit L1+L2+L3 m Total liquid piping length h m Drop between every two indoor units H + m Drop between the outdoor unit and the indoor unit H - m Drop between the outdoor unit and the indoor unit Standard 6.35 9.52 *10 *10 *10 *30 *1 *5 *5 Maximum / / *25 *25 *25 *45 *5 *15 *10 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

7
L1
L2
L3
h
H +
A
B
C
H -
The piping length information, please refer the following table.
Descriptions
Standard
A, B, Cliquid pipe
A, B, C Gas pipe
mm
Item
Maximum
Unit
L1
(one way)
L2
(one way)
L3
(one way)
h
H +
H -
mm
m
m
m
m
m
m
Size of the liquid side connection pipe
Pipe length when the compressor connects with two indoor units
Drop between every two indoor units
Drop between the outdoor unit and the indoor unit
*
10
*1
*5
*5
/
/
Size of the gas side connection pipe
Pipe length when the compressor connects with two indoor units
Pipe length when the compressor connects only one indoor unit
Drop between the outdoor unit and the indoor unit
6.35
9.52
*10
*10
*25
*5
*15
*10
*25
*25
L1+L2+L3
m
Total liquid piping length
*30
*45
Limitations on the installation
3. Limitations values on the piping work .