Haier H2SM-18HC03 User Manual - Page 15

Emergency and Test, Operation

Page 15 highlights

Operation Emergency and Test Operation Emergency operation: Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation. In this operation, it is possible to change the settings of temperature and air flow speed, it is Pi also impossible to do an operation by the timer. Follow the requirements below. Room Designated Timer temperature temperature mode Air flow Operation speed mode More than 23oC 26oC CONTINUOUS AUTO COOL Less than 23oC 23oC CONTINUOUS AUTO HEAT If an air conditioner is a model for both cooling and heating. Cooling when the room temperature at the start of operation is above 23oC. Heating when the room temperature at the start of operation is below 23oC Test operation: Use this switch in the test operation when the room temperature is less 16oC, do not use it in the normal operation. Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch, the cooling operation starts with the air flow speed setting "Hi". Pi...Pi Removal of the restriction of emergency or test operation: Press once more the emergency operation switch, or manipulate through the remote controller, a "Pi" sound causes the restriction of emergency or test operation to be removed. When the remote controller is manipulated for the removal, then the selected operation by the remote controller. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Pi
Pi...Pi
14
Emergency and Test
Operation
Use this operation only when the remote controller is defective or lost.
When the emergency operation switch is pressed,the" Pi "sound is heard once, which
means the start of this operation.
In this operation, it is possible to change the
settings of temperature and air flow speed, it is
also impossible to do an operation by the timer.
Operation
Emergency operation:
Follow the requirements below.
Room
temperature
Designated
temperature
Timer
mode
Air flow
speed
Operation
mode
More than 23
o
C
Less than 23
o
C
23
o
C
26
o
C
CONTINUOUS
CONTINUOUS
AUTO
AUTO
COOL
HEAT
If an air conditioner is a model for both cooling and heating.
Cooling when the room temperature at the start of operation is above 23
o
C.
temperature is less 16
o
C, do not use it in the normal
Use this switch in the test operation when the room
operation.
operation starts with the air flow speed setting "Hi".
Continue to press the test operation switch for more
than 5 seconds. After you hear the "Pi" sound twice,
release your finger from the switch, the cooling
Removal of the restriction of emergency or test operation:
Press once more the emergency operation switch, or manipulate through the remote
controller, a "Pi" sound causes the restriction of emergency or test operation to be
removed.
When the remote controller is manipulated for the removal, then the selected operation
by the remote controller.
Heating when the room temperature at the start of operation is below 23
o
C
Test operation: