Emergency operation: • Use this operation only when the remote controller is defective or lost. • When the emergency operation switch is pressed,the " Pi "sound is heard once, which means the start of this operation. • In this operation , the system automatically selects the operation mode , cooling or heating , according to the room temperature , as follows . Operation Designated Timer Air temperature mode temperature mode flow ABOVE 23°C COOLING 26 °C NONE AUTOMATIC BELOW 23°C HEATING 23 °C NONE AUTOMATIC • It is not possible to operate in dry mode. Test operation: Test operation switch is the same as emergency switch. • Use this switch in the test operation when the room temperature is below 16°C, do not use it in the normal operation. • Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed setting "Hi". • If the test operation switch is pressed more than 10 second, it will appear the trouble code. • After 30 minute, test opretation ends automatically. Pi J Pi...Pi Pi A Termination of emergency or test operation: • Press once more the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated. • When the remote controller is manupulated, it gets the system back to the normal operation mode. 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

Emergency
operation:
Use
this
operation
only
when
the
remote
controller
is
defective
or
lost.
When
the
emergency
operation
switch
is
pressed,the
"
Pi
"sound
is
heard
once,
which
means
the
start
of
this
operation.
In
this
operation
,
the
system
automatically
selects
the
operation
mode
,
cooling
or
heating
,
according
to
the
room
temperature
,
as
follows
.
temperature
Operation
mode
Designated
temperature
Timer
mode
Air
flow
ABOVE
23°C
COOLING
26
°C
NONE
AUTOMATIC
BELOW
23°C
HEATING
23
°C
NONE
AUTOMATIC
It
is
not
possible
to
operate
in
dry
mode.
Pi
J
Test
operation:
Test
operation
switch
is
the
same
as
emergency
switch.
Use
this
switch
in
the
test
operation
when
the
room
temperature
is
below
16°C,
do
not
use
it
in
the
normal
operation.
Continue
to
press
the
test
operation
switch
for
more
than
5
seconds.
After
you
hear
the
"Pi"
sound
twice,
release
your
finger
from
the
switch:
the
cooling
operation
starts
with
the
air
flow
speed
setting
"Hi".
If
the
test
operation
switch
is
pressed
more
than
10
second,
it
will
appear
the
trouble code.
After
30
minute,
test
opretation
ends
automatically.
Pi.
..Pi
Pi
A
Termination
of
emergency
or
test
operation:
Press
once
more
the
emergency
operation
switch
once
more,
or
manipulate
through
the
remote
controller;
the
"Pi"
sound,
the
emergency
or
test
operation
is
terminated.
When
the
remote
controller
is
manupulated,
it
gets
the
system
back
to
the
normal
operation
mode.
20