CAUTIONS All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries. Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver. Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit. 4. The wiring method should be in line with the local wiring standard. 5. The power cable and connecting cable are self-provided. The requirement of the power cable: Model AB242ACNAC AU242AANAC (HBU-24CL03/R1) AB282ACBAC AU282AABAC (HBU-28HL03/R1) AB242ACBAC AU242AABAC (HBU-24HL03/R1) H07RN-F 3G 4.0mm2 AB28NACNAC AU28NAANAC (HBU-28CM03/R1) AB36NACNAC AU36NAANAC (HBU-36CM03/R1) AB42NACNAC AU42NAANAC (HBU-42CM03/R1) AB36NACBAC AU36NAABAC (HBU-36HM03/R1) AB42NACBAC AU42NAABAC (HBU-42HM03/R1) H07RN-F 5G 2.5mm2 Specifications The refrigerating circuit is leak-proof. The connecting cable should be H05RN-F 4G 0.75mm. All the cables shall have got the European The machine is adaptive in following authentication certificate. situation 6. The breaker of the air conditioner should 1. Applicable ambient temperature range: Indoor Maximum: D.B / W.B 32 C/ 23 C Cooling Minimum: D.B / W.B 18 C/ 14 C Outdoor Maximum: D.B 43 C/ 26 C Minimum: D.B 15 C Indoor Maximum: D.B 27 C Minimum: D.B 20 C Heating Maximum: D.B / W.B 24 C/ 18 C Outdoor Minimum: D.B / W.B -7 C/ -8 C 2. If the supply cord is damaged, it must be be all-pole switch; and the distance between its two contacts should be no less 3mm. Such means for disconnection must be incorporation in the fixed wiring. 7. The waste battery shall be disposed properly. 8. The indoor unit installation height is at least 2.5m. 9. The power supply connects from the outdoor unit replaced by the manufacturer or its service agentor a similar qualified person. 3. If the fuse on PC board is broken please change it with the type of T. 3.15A /250VAC. 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

CAUTIONS
2
All electrical repairs must be carried out
by qualified electricians. Inadequate repairs
may result in a major source of danger for
the user of the air conditoiner.
Do not damage any parts of the air
conditioner that carry refrigerant by
piercing or perforating the air conditioner's
tubes with sharp or pointed items, crushing
or twisting any tubes, or scraping the
coatings off the surfaces. If the refrigerant
spurts out and gets into eyes, it may result
in serious eye injuries.
Do not obstruct or cover the ventilation
grille of the air conditioner. Do not put
fingers or any other things into the
inlet/outlet and swing louver.
Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following
situation
Cooling
Heating
Indoor
Maximum:
Minimum:
D.B / W.B
D.B / W.B
D.B
Outdoor
Maximum:
Minimum:
D.B
D.B
Indoor
Maximum:
Minimum:
D.B
Outdoor
Maximum:
Minimum:
43 C/ 26 C
D.B / W.B
24 C/ 18 C
20 C
27 C
15 C
18 C/ 14 C
32 C/ 23 C
AB242ACNAC
AU242AANAC
(HBU-24CL03/R1)
Model
H07RN-F
5G 2.5mm
2
H07RN-F
3G 4.0mm
2
2. If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agentor a similar qualified person.
3. If the fuse on PC board is broken please
change it with the type of
T. 3.15A /250VAC.
AB28NACNAC
AU28NAANAC
(HBU-28CM03/R1)
AB36NACNAC
AU36NAANAC
(HBU-36CM03/R1)
AB42NACNAC
AU42NAANAC
(HBU-42CM03/R1)
AB36NACBAC
AU36NAABAC
(HBU-36HM03/R1)
AB42NACBAC
AU42NAABAC
(HBU-42HM03/R1)
4. The wiring method should be in line with
the local wiring standard.
5. The power cable and connecting cable
are self-provided. The requirement of the
power cable:
The connecting cable should be
H05RN-F
4G 0.75mm.
All the cables shall have got the European
authentication certificate.
6. The breaker of the air conditioner should
be all-pole switch; and the distance between
its two contacts should be no less 3mm.
Such means for disconnection must be
incorporation in the fixed wiring.
7. The waste battery shall be disposed
properly.
8. The indoor unit installation height is at
least 2.5m.
9. The power supply connects from the
outdoor unit
AB242ACBAC
AU242AABAC
(HBU-24HL03/R1)
AB282ACBAC
AU282AABAC
(HBU-28HL03/R1)
D.B / W.B
-7 C/ -8 C