Operating, Instruction
UPC - 688057347516
View all Haier HD308 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
English Operating Instruction It is normal for the surrounding air to become slightly warmer as the dehumidifier operates. This warming effect further reduces the relative humidity of the surrounding air. There are 2 ways to remove collected water. (NOTE: The drain hose is not included with the unit. The direct drain feature is intended for use in basements inclusive of a floor drain only.) 1. Using the bucket Proper installation of the bucket is crucial in maintaining reliable dehumidifier operation. The bucket holds accumulated condensed water and by means of a safety switch controls both the water level and operation of the dehumidification process. IMPORTANT: Never tamper with or attempt to defeat the water level (safety ) float switch system. Using the bucket Using a hose Sealing element Hose Sealing cover Sealing cover 2. Using Direct Drainage The direct drainage feature can be activated using the following steps. 1. Remove the plastic cap at the rear of the unit. (Keep the rubber insert well for use later. 1 ) Fig. #1 0 2. Screw the purchased garden hose to the direct drain opening tightly. (Fig. #2) Fig. #2 0 3. Position the dehumidifier as close as you can to the floor drain. 4. Position the opening end of the drain hose directly over the floor drain and start the unit. 5. When the direct drain feature is not being used, remove the drain hose from the direct drain opening and plug it with the rubber cap provided. 4