Haier HLTD600AGW User Manual - Page 20
Part B - 3-wire Power Cord
View all Haier HLTD600AGW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
A1. A ttach the power cord ground wire (green) to the cabinet with the green ground screw. Tighten the screw securely. A2. A ttach the power cord neutral wire (white) and the neutral ground jumper wire (white) with the center terminal block screw. Tighten the screw securely. A3. A ttach the remaining 2 power cord line wires (red and black) with the outer terminal block screws. Attach one wire to each terminal block as shown. Tighten both screws securely. IMPORTANT: Do not make a sharp bend or crimp the wires at connections. PART B - 3-WIRE POWER CORD a c b d e f a Terminal Block Screw b Ground Screw (Green) c Neutral-Ground Jumper Wire (White) d Power Cord Line Wires (One Red; One Black) e Power Cord Neutral Wire (White) f Power Cord B1. A ttach the power cord neutral wire (white) to the center terminal block screw. Tighten the screw securely. B2. A ttach the remaining 2 power cord line wires (red and black) with the outer terminal block screws. Attach one wire to each terminal block as shown. Tighten both screws securely. B3. Attach the neutral ground jumper wire (white) to the cabinet with the green ground screw. Tighten the screw securely. IMPORTANT: Do not make a sharp bend or crimp the wires at connections. 18