Haier HM-07C03 User Manual - Page 12

Check, troubles

Page 12 highlights

Check on troubles by self Please check the following points before applying for repair or service.If the trouble is not solved,please contact the sellers. Phenomenon Checking content Measurements Press "1/0"but cannot start 1.Is the power plug inserted into the outlet reliably? the machine 2.Does the Water Full indicator light up? 3.Is the water tank placed well? Please insert the power plug into the outlet reliably. Pour out the water in the tank (refer to P6) Please push the tank to right position. The LCD window displays Is the Time On timer set? mode,but can not run it. It will automatically run when the set time is up. Set to cool,but find no cold Is the indoor temperature air (the LCD window below 15°C,or it is under 3 displays the mode). minutes delaying? The indoor temperature is below 15°C.It is normal phenomenon. If the indoor temperature is It is in defrost mode. After above 15°C, pull the filter bar defrosting the running indicator open to see if there's frost on of the compressor will be the surface of the evaporator. on,and it will start running. Set to Dehumidify,but find Pull the filter bar open. no cold air(the LCD wind- There's frost on the surface ow displays the mode) of the evaporator. It is running defrosting .After defrosting the running indicator of the compressor will be on,and it will start running. The air rate is too low Is the filter screen blocked with Please clean the filte screen dust? (refer to P8) Is there barrier at the wind gap? The power plug and outlet Are the jacks of the outlet are too hot too loose? Is the filter screen too dirty? If it is loose please send it to the department where you bought the machine to repair. The noise and vibration in Is the machine used in running are too large slanting place? Please put it on horizontal ground. There's abnormal sound There's sound of running water in running or when the machine is just stopped. It is the sound of the inner liquid (refrigerating medium), not abnormal phenomenon. There's cracking sound in running It is the sound of the components shrinking and expanding against changes of temperature,not abnormal phenomenon. -11-

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

Check
on
troubles
by
self
Please
check
the
following
points
before
applying
for
repair
or
service.If
the
trouble
is
not
solved,please
contact
the
sellers.
Phenomenon
Checking
content
Measurements
Press
"1/0"but
cannot
start
the
machine
1.Is
the
power
plug
inserted
into
the
outlet
reliably?
Please
insert
the
power
plug
into
the
outlet
reliably.
2.Does
the
Water
Full
indicator
light
up?
Pour
out
the
water
in
the
tank
(refer
to
P6)
3.Is
the
water
tank
placed
well?
Please
push
the
tank
to
right
position.
The
LCD
window
displays
mode,but
can
not
run
it.
Is
the
Time
On
timer
set?
It
will
automatically
run
when
the
set
time
is
up.
Set
to
cool,but
find
no
cold
air
(the
LCD
window
displays
the
mode).
Is
the
indoor
temperature
below
15°C,or
it
is
under
3
minutes
delaying?
The
indoor
temperature
is
below
15°C.It
is
normal
phenomenon.
If
the
indoor
temperature
is
above
15°C,
pull
the
filter
bar
open
to
see
if
there's
frost
on
the
surface
of
the
evaporator.
It
is
in
defrost
mode.
After
defrosting
the
running
indicator
of
the
compressor
will
be
on,and
it
will
start
running.
Set
to
Dehumidify,but
find
no
cold
air(the
LCD
wind-
ow
displays
the
mode)
Pull
the
filter
bar
open.
There's
frost
on
the
surface
of
the
evaporator.
It
is
running
defrosting
.After
defrosting
the
running
indicator
of
the
compressor
will
be
on,and
it
will
start
running.
The
air
rate
is
too
low
Is
the
filter
screen
blocked
with
dust?
Is
there
barrier
at
the
wind
gap?
Please
clean
the
filte
screen
(refer
to
P8)
The
power
plug
and
outlet
are
too
hot
Are
the
jacks
of
the
outlet
too
loose?
Is
the
filter
screen
too
dirty?
If
it
is
loose
please
send
it
to
the
department
where
you
bought
the
machine
to
repair.
The
noise
and
vibration
in
running
are
too
large
Is
the
machine
used
in
slanting
place?
Please
put
it
on
horizontal
ground.
There's
abnormal
sound
There's
sound
of
running
water
in
running
or
when
the
machine
is
just
stopped.
It
is
the
sound
of
the
inner
liquid
(refrigerating
medium),
not
abnormal
phenomenon.
There's
cracking
sound
in
running
It
is
the
sound
of
the
components
shrinking
and
expanding
against
changes
of
temperature,not
abnormal
phenomenon.
-11-