Trouble shooting Followings are not problems Sound of water flowings are not problems. During unit start and operation or at stop, a swishing or gurgling noise may be heard. This noise is generated by refrigerant flowing in the system. Sound of cracking is heard. During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperatuer changes. Smells are generated. This is because the system circulates smells from the interior air such as the smell of cigarettes or the painting on the unit. During operation, white fog or steam comes out of indoor unit. When unit is running at places like restaurant where dense edible oil fumeis always exist, this will happen. In cooling operation, unit switches to fan operation. Unit will not restart after stop. Won't start? No outlet air or fan speed can't be changed in dry mode. In heating operation, water or steam are blown out of indoor unit. To prevent frost from accumulating on indoor heat exchanger, unit will switch to fan operation for a while then resume cooling operation. Though ON/OFF button is set to ON, unit won't resume cooling, dry or heating operation in 3 min after it is stopped, this is because of 3-min-delay protection circuit. Please wait 3 minutes Unit will reduce fan speed repeatedly and automatically if room temp. is too low in dry operation. This occurs when frost accumulated on the outdoor unit is removed. (during defrosting operation) In heating operation, indoor fan won't stop even if unit is stopped. After unit stops, indoor fan will go on running until indoor unit cools down. 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

Trouble shooting
20
Followings are not problems
Sound of water flowings are
not problems.
Sound of cracking is heard.
Smells are generated.
During operation, white fog or
steam comes out of indoor unit.
In cooling operation, unit switches to fan
operation.
Unit will not restart after stop.
Won't start?
No outlet air or fan speed can't be changed
in dry mode.
In heating operation, water or steam are
blown out of indoor unit.
In heating operation, indoor fan won't stop
even if unit is stopped.
During unit start and operation or at stop, a swishing
or gurgling noise may be heard. This noise is generated
by refrigerant flowing in the system.
During unit operation, a cracking noise may be heard.
This noise is generated by the casing expanding or
shrinking because of temperatuer changes.
This is because the system circulates smells from the
interior air such as the smell of cigarettes or the
painting on the unit.
When unit is running at places like restaurant where
dense edible oil fumeis always exist, this will happen.
To prevent frost from accumulating on indoor heat
exchanger, unit will switch to fan operation for a while
then resume cooling operation.
Though ON/OFF button is set
to ON, unit won't resume cooling,
dry or heating operation
in 3 min after it is stopped, this
is because of 3-min-delay
protection circuit.
Unit will reduce fan speed repeatedly and automatically
if room temp. is too low in dry operation.
This occurs when frost accumulated
on the outdoor unit is removed.
(during defrosting operation)
After unit stops, indoor fan will go on running
until indoor unit cools down.
Please wait 3 minutes