Haier HSU-09C12 User Manual - Page 5

When connecting the cable before installing the indoor unit

Page 5 highlights

Indoor unit When connecting the cable before installing the indoor unit Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC. 57(YZW). 2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V. 3. The wiring method should be in line with the local wiring standard. 4. After installation, the power plug should be easily reached. 5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. 4 1(L) 2(N) 1(L) 2(N) { { Indoor unit HSU-09C12 HSU-12C12 HSU-09C13 HSU-12C13 HSU-12C03/Z1 Outdoor unit LN G N L Indoor unit POWER PLUG HSU-18C13 HSU-18CK03 Outdoor unit 1(L) 2(N) 4 Indoor unit HSU-09C03/Z1 Outdoor unit G N L LN Power cable: -mod 09-12: -mod 18-24: 3G1.0mm 2 3G2.0mm 2 Connecting cable: -mod 09-12: 3G1.0mm 2 -mod 18-24: 3G2.0mm 2 Indoor unit POWER PLUG HSU-22C13 HSU-24C13 Outdoor unit 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

Indoor unit
1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
qualified person. The type of connecting wire is
H05/07RN-F or 245IEC57(YZW).
.
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
When connecting the cable before installing the indoor unit
Insert the cable from the back side of the unit, then pull it out on the front side.
Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.
Pull the cable slightly to make sure the cables have been properly inserted and tightened.
After the cable connection, never fail to fasten the connected cable with the wiring cover.
Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring
is not correct, proper operation can not be carried out and will cause defect.
5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch
and the
distance between its two contacts should be not less than 3mm.
HSU-09C12
HSU-12C12
Indoor unit
Indoor unit
Outdoor unit
Outdoor unit
HSU-09C13
HSU-12C13
HSU-18C13
Indoor unit
Outdoor unit
4
Indoor unit
Outdoor unit
HSU-12C03/Z1
HSU-09C03/Z1
Connecting cable:
3G1.0mm
-mod 09-12:
2
3G2.0mm
-mod 18-24:
2
HSU-18CK03
Power cable:
3G1.0mm
-mod 09-12:
2
3G2.0mm
-mod 18-24:
2
)
L
(
1
)
N
(
2
)
L
(
1
)
N
(
2
L
N
G
U
L
P
R
E
W
O
P
{
L
N
G
4
HSU-24C13
HSU-22C13
)
L
(
1
)
N
(
2
L
N
G
U
L
P
R
E
W
O
P
{
L
N
G
5