Page 3 highlights

Specifications Electrical Rating Inlet / Outlet Diameter Maximum Flow Maximum Suction Lift Maximum Delivery Height Start Pressure Stop Pressure Power Cord Length 120V~ / 60Hz / 10 A 1 IN. NPT 976 GPH 26 FT. 150 FT. 22 PSI 65 PSI 6 FT. Installation Note: Do not install the pump by suspending it unsupported from its power cord or discharge hose. The pump must be suspended from the handle. Remove Shipping Plug before installation. Installing 1. Thread the Pressure Control Box onto the water outlet on the top of the Pump. 2. Set the Pump horizontally on a level, solid and dry foundation. 3. Secure the Pump to the mounting surface by installing bolts (not included) through the mounting holes in the base plate. 4. The Pump is supplied with 1" NPT connections to be fitted in the suction and discharge ports. See Figure 1. 5. If the Pump is installed with long pipes (as shown), the pipes must be properly supported on either side of the Pump to prevent straining the connections. If the Pump is drawing water from a well, fit a foot valve (not included) to the end of the suction pipe. WARNING! Do not allow the Pump to get wet. Note: The maximum delivery height of the Pump is 32 feet. Item 69303 For technical questions, please call 1-800-444-3353. Page 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Page 3
For technical questions, please call 1-800-444-3353.
Item 69303
Specifications
Electrical Rating
120V~ / 60Hz / 10
A
Inlet / Outlet Diameter
1 IN. NPT
Maximum Flow
976 GPH
Maximum Suction Lift
26 FT.
Maximum Delivery Height
150 FT.
Start Pressure
22 PSI
Stop Pressure
65 PSI
Power Cord Length
6 FT.
Installation
Note:
Do not install the pump by suspending it unsupported from its power cord or discharge hose.
The pump must be suspended from the handle. Remove Shipping Plug before installation.
Installing
1.
Thread the Pressure Control Box onto the
water outlet on the top of the Pump.
2.
Set the Pump horizontally on a level,
solid and dry foundation.
3.
Secure the Pump to the mounting surface
by installing bolts (not included) through
the mounting holes in the base plate.
4.
The Pump is supplied with 1" NPT
connections to be fitted in the suction
and discharge ports.
See Figure 1.
5.
If the Pump is installed with long pipes (as shown),
the pipes must be properly supported on either side
of the Pump to prevent straining the connections.
If the Pump is drawing water from a well, fit a foot
valve (not included) to the end of the suction pipe.
WARNING!
Do not allow the Pump to get wet.
Note:
The maximum delivery height