Harbor Freight Tools 69303 User Manual - Page 4
Automatic, Booster Pump
View all Harbor Freight Tools 69303 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
Operation Consider the following points before starting the pump: a. Verify that the pump rests on the floor. b. Verify that the delivery pipe is properly connected. c. Verify that the electrical connection is 120V~, 60 Hz. d. Verify that the electrical socket is in good condition. e. Verify that water and moisture cannot get near the power supply socket. f. Verify that the pump is installed so as to prevent running dry. g. Note the controls on the Pressure Control Box. This device will protect against rundry operation, overheating, improper starting, and pressure drops. Power Pump On Overheat 1-1/2 HORSEPOWER AUTOMATIC BOOSTER PUMP Restart NONSUBMERSIBLE PUMP ITEM 69303 120V~ / 10A ACCEPTABLE FOR INDOOR USE ONLY. Figure 1 See the label from the Pressure Control box in Figure 1 above, for LED indicators and restart button locations described below. 1. Remove the Priming Plug and fill the pump housing with water. 2. Turn on the water supply leading to the Pump. Open one tap at the outlet for air discharge before starting the Pump. 3. Plug in the power cord. The POWER LED will light, indicating that voltage is present. The Pump is ready to operate. 4. Turn the Power Switch on (I). NOTE: Once the system pressure raises above the stop pressure, the system will automatically shut off. It will automatically restart once the pressure drops below the start pressure. 5. Once the Pump is running and pumping water, the PUMP-ON LED will light. 6. Automatic Shut off: a. If no water is coming into the Pump, the OVERHEAT LED will light and the Pump will shut off. If this happens, turn off the Power Switch and wait for the pump to cool down. Correct the water supply, press the RESET button then turn the Power Switch on to restart the Pump. b. If the inside temperature of the Pump exceeds 158° F (70° C), the OVERHEAT LED will light and the Pump will shut off. If this happens, turn off the Power Switch and wait for the Pump to cool down. Then press the RESET button and turn the Power Switch on to restart the Pump. 7. WARNING! Do not turn or adjust the Automatic Pressure Controller. This is a pre-set connection and twisting it will cause the Pump to leak. 8. The Pump will stop automatically 10 seconds after the pressure inside the system reaches the stop pressure. 9. When finished using the Pump, turn the Power Switch off (O), unplug the unit. Page 4 For technical questions, please call 1-800-444-3353. Item 69303