Hayward 004952001000 HydraPure Technical Training Guide - Page 20
Clean the Quartz Tube cont.
View all Hayward 004952001000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Maintenance: Clean the Quartz Tube (cont.) Step 5 Step 6 Spring Clip Lamp Assy. Remove the spring clip and carefully lift the lamp assembly from the quartz tube. Do not pull on lamp wires. Set aside in a safe place. Step 7 Remove the round sealing nut by turning it counter clockwise. Remove compression washer. Do not to lose the black gasket. Step 8 *Grip quartz tube with both thumbs inside and pull up. Once O-ring breaks free the tube should lift out easily. Wear proper PPE, use a shower cleaner, CLR type cleaner, or a solution of white vinegar and water to clean the outside of the quartz tube. 20 *The quartz tube is fragile. Handle it carefully. Do not set it down on a hard surface or use abrasive cleaners or pads.
Remove the spring clip and carefully lift the
lamp assembly from the quartz tube.
Do not
pull on lamp wires.
Set aside in a safe place.
Remove the round sealing nut by turning it
counter clockwise.
Remove compression
washer.
Do not to lose the black gasket.
*Grip quartz tube with both thumbs inside and
pull up.
Once O-ring breaks free the tube
should lift out easily.
Wear proper PPE, use a shower cleaner, CLR
type cleaner, or a solution of white vinegar and
water to clean the outside of the quartz tube.
Step 7
Step 8
Step 5
Step 6
Maintenance:
Clean the Quartz Tube (cont.)
*The quartz tube is fragile.
Handle it carefully.
Do not set it
down on a hard surface or use abrasive cleaners or pads.
Spring
Clip
Lamp
Assy.
20