Hayward 004952001000 HydraPure Technical Training Guide - Page 20

Clean the Quartz Tube cont.

Page 20 highlights

Maintenance: Clean the Quartz Tube (cont.) Step 5 Step 6 Spring Clip Lamp Assy. Remove the spring clip and carefully lift the lamp assembly from the quartz tube. Do not pull on lamp wires. Set aside in a safe place. Step 7 Remove the round sealing nut by turning it counter clockwise. Remove compression washer. Do not to lose the black gasket. Step 8 *Grip quartz tube with both thumbs inside and pull up. Once O-ring breaks free the tube should lift out easily. Wear proper PPE, use a shower cleaner, CLR type cleaner, or a solution of white vinegar and water to clean the outside of the quartz tube. 20 *The quartz tube is fragile. Handle it carefully. Do not set it down on a hard surface or use abrasive cleaners or pads.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45

Remove the spring clip and carefully lift the
lamp assembly from the quartz tube.
Do not
pull on lamp wires.
Set aside in a safe place.
Remove the round sealing nut by turning it
counter clockwise.
Remove compression
washer.
Do not to lose the black gasket.
*Grip quartz tube with both thumbs inside and
pull up.
Once O-ring breaks free the tube
should lift out easily.
Wear proper PPE, use a shower cleaner, CLR
type cleaner, or a solution of white vinegar and
water to clean the outside of the quartz tube.
Step 7
Step 8
Step 5
Step 6
Maintenance:
Clean the Quartz Tube (cont.)
*The quartz tube is fragile.
Handle it carefully.
Do not set it
down on a hard surface or use abrasive cleaners or pads.
Spring
Clip
Lamp
Assy.
20