Hayward AQ-TROL-HP Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ- - Page 20

Questions?

Page 20 highlights

WEEKLY MONTHLY ELECTROLYTIC CHLORINE GENERATOR BASIC POOL MAINTENANCE REQUIREMENTS TEST IDEAL RANGE ADJUSTMENT REQUIRED Free Chlorine pH 1.0 - 3.0 ppm 7.2 - 7.8 Raise desired output % to increase, lower desired output % to decrease -OR- increase or decrease pump filtration time. Too high - add muriatic acid Too low - add soda ash. Alkalinity 80 - 120 ppm Add baking soda to increase. Add acid as required to decrease. Salt 2700 - 3400 ppm Add salt as required to increase. Stabilizer 60 - 80 ppm Add cyanuric acid to increase. Calcium 200 - 400 ppm Add calcium to increase. Drain and add water to decrease. Electrolytic Cell inspect & clean Refer to section in manual. Questions? Refer to www.goldlinecontrols.com for latest manual revisions, additional information and helpful service. QUARTERLY 620 Division St. Elizabeth, NJ 07207 092016K RevL Copyright © 2010 Hayward Inc.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Questions?
Refer to
www.goldlinecontrols.com
for latest manual
revisions, additional information and helpful service.
ELECTROLYTIC CHLORINE GENERATOR
BASIC POOL MAINTENANCE REQUIREMENTS
WEEKLY
MONTHLY
QUARTERLY
Free Chlorine
1.0 - 3.0 ppm
pH
7.2 - 7.8
Raise desired output % to
increase, lower desired output %
to decrease -OR- increase or
decrease pump filtration time.
Too low -
add soda ash.
Too high - add muriatic acid
Alkalinity
80 - 120 ppm
Salt
2700 - 3400 ppm
Add salt as required to increase.
Add baking soda to increase.
Stabilizer
60 - 80 ppm
Add cyanuric acid to increase.
Calcium
200 - 400 ppm
Add calcium to increase.
Electrolytic Cell
inspect & clean
Refer to section in manual.
TEST
IDEAL RANGE
ADJUSTMENT REQUIRED
Drain and add water to decrease.
Add acid as required to decrease.
092016K RevL
Copyright © 2010 Hayward Inc.
620 Division St.
Elizabeth, NJ
07207