Hayward Aqua Plus Controls plus Chlorination Model: PL-PLUS-16V Operation - Page 19

Heater Setpoints in Groups

Page 19 highlights

if AQL-SS-D is connected Digital Spa Config. + to view/change Select Digital Spa A Digital A, Button 1 Pool/Spa Digital A, Setpoint Heater1 Push to access the Digital Spa Side Remote options Move to previous/next configuration menu Rotates between all available remotes Move to next menu item Rotates between System Off, Pool/Spa, Filter, Lights, Heater1, Valve3, Valve4, and all available Aux outputs Move to previous/next menu item Rotates between heaters that are enabled Move to previous menu item or next configuration menu Select Digital Spa This menu only appears if more than one AQL-SS-D is detected at power up. Select which of the available remote controls (A, B or C) is to be configured. Digital A, Button 1 This menu allows the user to map each button of the AQL-SS-D to one of the standard Aqua Plus 16v functions. The default selections are: Button 1 - Pool/Spa, Button 2 - Filter, Button 3 - Lights, Button 4 - Heater1, Button 5 - Valve3, Button 6 - Valve4, Button 7 - Aux1 and Button 8 - Aux2. Digital A, Setpoint If more than one heater is installed, select the spa heater you wish to control. If no heaters are installed, "Heaters Disabled" will be displayed. Remote Menus Enabled Toggle between Enabled (default) and Disabled Remote Menus Move to previous/next configuration menu This feature will prevent unauthorized access to the Settings, Timers, and Configuration menus from any of the Aqua Plus 16v's remote display/keypads. When disabled, the remote display/keypads will only show the default menu and allow on/off control via the pushbuttons. Note that the function of the Aqua Plus 16v's built-in display/keypad is unchanged by this selection. Once disabled, the only way to enable "Remote Menus" is to use the local display/keypad. All Timeclocks 7-day Toggle between 7-day (default) and Weekend/Weekday time options Move to previous/next configuration menu This selection affects ALL of the timeclock logic in the Aqua Plus 16v. If "7-day" is selected, each timeclock will have one set of turn-on/turn-off settings that operate every day of the week. If "Weekend/ Weekdays" option is selected then the user can enter one set of turn-on/turn-off times for the weekend (fixed as Saturday/Sunday) and another set of turn-on/turn-off times for weekdays (Monday through Friday). Time Format 12 hour AM/PM Units ºF and PPM Toggle between 12 hour AM/PM (default) and 24 hour time format options Move to previous/next configuration menu Toggle between ºF and PPM (default) and ºC and g/L (Metric) options Move to previous/next configuration menu if any output is configured as a variable speed pump VSP Speed % Toggle between % and RPM Move to previous/next configuration menu This is the unit of measure for displaying the speed of the variable speed pump. Select % of your pump's maximum speed or revolutions per minute (RPM). 31 A table of functions and their corresponding control parameters are listed below. Function Pool/Spa Pool Filter Lights (standard relay) Lights (dimmer relay) Spa Filter Aux1-14 (standard relay) Aux1-14 (dimmer relay) Valve3 Valve4 Spa Htr1 Set Pool Htr1 Set Spa Htr2 Set Pool Htr2 Set Spa Solar Set Pool Solar Set SuperChlr Spa High Spa Low Pool High Pool Low Control Parameter Unaffected, Pool only, Spa only, or Spillover Unaffected, Off, On, High speed, or Low speed Unaffected, Off, or On Unaffected, Off, On, 100%, 80%, 60%, 40%, or 20% Unaffected, Off, On, High speed, or Low speed Unaffected, Off, or On Unaffected, Off, On, 100%, 80%, 60%, 40%, or 20% Unaffected, Off, or On Unaffected, Off, or On Unaffected, Off, 65º-104ºF Unaffected, Off, 65º-104ºF Unaffected, Off, 65º-104ºF Unaffected, Off, 65º-104ºF Unaffected, Off, 65º-104ºF Unaffected, Off, 65º-104ºF Unaffected, Off, On Unaffected, 20% to Highest speed Unaffected, Lowest speed to 50% Unaffected, 20% to Highest speed Unaffected, Lowest speed to 50% Note that all functions in the table may not be offered. The available functions are dependent on how the Aqua Plus 16v is configured. For example, if the Aqua Plus 16v is configured for a single heater, "Heater2" will not be available as an option in the Group menu. Also, under some circumstances, functions will be displayed but can't be changed. Note that the function whose menu you are in, will not be displayed as an option and will automatically turn on when the group is activated. For example, if programming a Group function under the Lights menu, the Lights function will not be offered as an option and the Lights function will automatically turn on with the group. The available control parameters vary with each function. All functions offer "Unaffected", which should be selected if you do not wish to control that particular function within the group. All other parameters will depend on the particular function selected. When activating Group functions, be aware that the most recent Group function that you activate will override any previous Group functions. Heater Setpoints in Groups The Aqua Plus 16v can be programmed to use alternate heater setpoints (conventional and/or solar) while running group commands. This allows the heater to be set to a higher or lower temperature than normal, while the group is activated. When the group stops, the setpoint will return to its normal setting. Changing the setpoint while the Group is running will make the Group release the alternate setpoint control and revert back to the normal heater setting. Any changes that are made at that point will affect the normal heater setting. The next time the Group is activated, the temperature will return to the group setpoint that was originally programmed in the Configuration Menu. To change the setpoint while the Group is running, go to the Settings menu and press the +/- button while "Group Control" is displayed. The setpoint will change and be retained as the new normal heater setpoint. 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

16
A table of functions and their corresponding control parameters are listed below.
Note that all functions in the table may not be offered.
The available functions are dependent on how the Aqua Plus
16v is configured.
For example, if the Aqua Plus 16v is configured for a single heater, “Heater2” will not be
available as an option in the Group menu.
Also, under some circumstances, functions will be displayed but can’t be
changed. Note that the function whose menu you are in, will not be displayed as an option and will automatically
turn on when the group is activated. For example, if programming a Group function under the Lights menu, the
Lights function will not be offered as an option and the Lights function will automatically turn on with the group.
The available control parameters vary with each function.
All functions offer “Unaffected”, which should be
selected if you do not wish to control that particular function within the group.
All other parameters will depend on
the particular function selected.
When activating Group functions, be aware that the most recent Group function that you activate will override any
previous Group functions.
Heater Setpoints in Groups
The Aqua Plus 16v can be programmed to use alternate heater setpoints (conventional and/or solar) while running
group commands. This allows the heater to be set to a higher or lower temperature than normal, while the group is
activated. When the group stops, the setpoint will return to its normal setting.
Changing the setpoint while the Group is running will make the Group release the alternate setpoint control and
revert back to the normal heater setting. Any changes that are made at that point will affect the normal heater
setting.
The next time the Group is activated, the temperature will return to the group setpoint that was originally
programmed in the Configuration Menu. To change the setpoint while the Group is running, go to the Settings menu
and press the +/- button while “Group Control” is displayed.
The setpoint will change and be retained as the new
normal heater setpoint.
31
Digital Spa Config.
+ to view/change
Digital A,
Button 1
Pool/Spa
Digital A,
Setpoint
Heater1
Select Digital Spa
A
Push to access the Digital Spa Side Remote options
Rotates between System Off, Pool/Spa, Filter, Lights, Heater1, Valve3,
Valve4, and all available Aux outputs
Rotates between heaters that are enabled
Rotates between all available remotes
Move to previous/next configuration menu
Move to previous/next menu item
Move to previous menu item or next configuration menu
Move to next menu item
if AQL-SS-D is connected
Select Digital Spa
This menu only appears if more than one AQL-SS-D is detected at power up.
Select which of the
available remote controls (A, B or C) is to be configured.
Digital A,
Button 1
This menu allows the user to map each button of the AQL-SS-D to one of the standard Aqua Plus 16v
functions.
The default selections are:
Button 1 - Pool/Spa, Button 2 - Filter, Button 3 - Lights, Button
4 - Heater1, Button 5 - Valve3, Button 6 - Valve4, Button 7 - Aux1 and Button 8 - Aux2.
Digital A,
Setpoint
If more than one heater is installed, select the spa heater you wish to control.
If no heaters are
installed, “Heaters Disabled” will be displayed.
Remote Menus
Enabled
Toggle between Enabled (default) and Disabled Remote Menus
Move to previous/next configuration menu
This feature will prevent unauthorized access to the Settings, Timers, and Configuration menus from
any of the Aqua Plus 16v’s remote display/keypads.
When disabled, the remote display/keypads will
only show the default menu and allow on/off control via the pushbuttons.
Note that the function of
the Aqua Plus 16v’s built-in display/keypad is unchanged by this selection.
Once disabled, the only
way to enable “Remote Menus” is to use the local display/keypad.
All Timeclocks
7-day
Move to previous/next configuration menu
Toggle between 7-day (default) and Weekend/Weekday time options
This selection affects ALL of the timeclock logic in the Aqua Plus 16v.
If
“7-day” is selected, each
timeclock will have one set of turn-on/turn-off settings that operate every day of the week.
If “Weekend/
Weekdays” option is selected then the user can enter one set of turn-on/turn-off times for the weekend
(fixed as Saturday/Sunday) and another set of turn-on/turn-off times for weekdays (Monday through
Friday).
Time Format
12 hour AM/PM
Units
ºF and PPM
Move to previous/next configuration menu
Move to previous/next configuration menu
Toggle between 12 hour AM/PM (default) and 24 hour time format options
Toggle between ºF and PPM (default) and ºC and g/L (Metric) options
VSP Speed
%
Toggle between % and RPM
Move to previous/next configuration menu
if any output is configured as a
variable speed pump
This is the unit of measure for displaying the speed of the variable speed pump.
Select % of your
pump’s maximum speed or revolutions per minute (RPM).
Pool/Spa
Unaffected, Pool only, Spa only, or Spillover
Pool Filter
Unaffected, Off, On, High speed, or Low speed
or
Function
Control Parameter
Lights
Unaffected, Off, or On
Lights
Unaffected, Off, On, 100%, 80%, 60%, 40%, or 20%
Spa Filter
Unaffected, Off, On, High speed, or Low speed
Aux1-14
Unaffected, Off,
On
Aux1-14
Unaffected, Off, On, 100%, 80%, 60%, 40%, or 20%
Valve3
Unaffected, Off, or On
Valve4
Unaffected, Off, or On
Spa Htr1 Set
Unaffected, Off, 65º-104ºF
Pool Htr1 Set
Unaffected, Off, 65º-104ºF
Spa Htr2 Set
Unaffected, Off, 65º-104ºF
Pool Htr2 Set
Unaffected, Off, 65º-104ºF
Spa Solar Set
Unaffected, Off, 65º-104ºF
Pool Solar Set
Unaffected, Off, 65º-104ºF
SuperChlr
Unaffected, Off, On
Spa High
20% to Highest speed
Spa Low
Lowest speed to 50%
Pool
H
(standard relay)
(dimmer relay)
(s
(dimmer relay)
tandard relay)
Unaffected,
Unaffected,
High
Unaffected, 20% to
ighest speed
Pool Low
Unaffected, Lowest speed to 50%