Hayward E-Command 4 Model: ALL MODELS Operation - Page 17

Spa Spillover, Filter Operation, V1=Aux1, V2=Aux2, Filter Off Valve Change, Filter Pump

Page 17 highlights

Spa Spillover When spa spillover is "Enabled" and "Pool and Spa", the homeowner will be able to rotate through "Pool Only" (both suction and return valves switched to pool), "Spa Only" (both suction and return valves switched to spa) and "Spillover" (suction valve switched to pool and return valve switched to spa) by successive presses of the "Pool/Spa button. Filter Operation If "Spa Spillover" is selected, the ECOMMAND 4 will automatically switch the pool/spa suction and return valves to "spillover" at the start of the programmed pool filtering time period or when the super-chlorinate function is turned on. The valves will remain in this position for the remainder of the super-chlorinate period. This option is usually preferable because both the pool and spa water will be filtered and sanitized. If "Pool Only" is selected, then the ECOMMAND 4 will switch the pool/spa valves to the "pool only" position at the start of the programmed pool filtering time period or when the super-chlorinate function is turned on. This may be desirable on some systems with in-floor cleaners because it allows the cleaner to operate all the time the pool is being filtered and/or the super chlorinate is running. V1=Aux1, V2=Aux2 This menu appears only if the Pool/Spa Setup is "Pool Only" or "Spa Only". When enabled, Valve 1 (return) will follow the Aux1 output and Valve 2 (suction) will follow the Aux2 output. When disabled (default), the return and suction pool/spa valves function normally. Filter Off Valve Change This menu appears only if Pool/Spa setup is set to "Pool and Spa - Std". When enabled (default), the filter pump will shut off for 35 seconds whenever the Pool/Spa valves are turning. The pump will NOT shut off when a heater is in Heater Cooldown mode. Filter Config. + to view/change Push to access pump options Move to previous/next configuration menu Filter Pump 1 Speed if "Variable Speed" is selected Lowest Speed 10% if "Variable Speed" is selected Highest Speed 100% Rotates between 1-speed (default), 2-speed and variable speed options Move to next menu item Adjust the lowest speed desired for variable speed operation Move to next menu item Adjust the highest speed desired for variable speed operation Move to next menu item Freeze Protect Enabled Toggle between Enabled (default) and Disabled Freeze Protection Move to next menu item or previous/next configuration menu if "Freeze Protect" is enabled and "1-speed Filter" is not selected Freeze Protect Toggle between high speed (default) and low speed High Speed Move to next menu item if "Freeze Protect" is enabled Freeze Temp Adjust the desired freeze protection temperature (33ºF - 42ºF) 38ºF Move to previous/next configuration menu Filter Pump For 2-speed pumps: When a 2-speed pump is configured, one of the AUX relays must also be configured to control the low speed motor winding on the pump. Refer to the appropriate sections in the Installation manual for specific information regarding the control logic for 2speed and variable speed pump operation. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

14
Spa Spillover
When spa spillover is “Enabled” and “Pool and Spa”, the homeowner will be able to rotate
through “Pool Only” (both suction and return valves switched to pool), “Spa Only” (both
suction and return valves switched to spa) and “Spillover” (suction valve switched to pool
and return valve switched to spa) by successive presses of the “Pool/Spa button.
Filter Operation
If “Spa Spillover” is selected, the ECOMMAND 4 will automatically switch the pool/spa
suction and return valves to “spillover” at the start of the programmed pool filtering time
period or when the super-chlorinate function is turned on.
The valves will remain in this
position for the remainder of the super-chlorinate period.
This option is usually preferable
because both the pool and spa water will be filtered and sanitized.
If “Pool Only” is selected, then the ECOMMAND 4 will switch the pool/spa valves to the
“pool only” position at the start of the programmed pool filtering time period or when the
super-chlorinate function is turned on.
This may be desirable on some systems with in-floor
cleaners because it allows the cleaner to operate all the time the pool is being filtered and/or
the super chlorinate is running.
V1=Aux1, V2=Aux2
This menu appears only if the Pool/Spa Setup is “Pool Only” or “Spa Only”.
When enabled,
Valve 1 (return) will follow the Aux1 output and Valve 2 (suction) will follow the Aux2 output.
When disabled (default), the return and suction pool/spa valves function normally.
Filter Off Valve Change
This menu appears only if Pool/Spa setup is set to “Pool and Spa - Std”.
When enabled
(default), the filter pump will shut off for 35 seconds whenever the Pool/Spa valves are
turning.
The pump will NOT shut off when a heater is in Heater Cooldown mode.
Filter Config.
+ to view/change
Filter Pump
1 Speed
Freeze Protect
Enabled
Lowest Speed
10%
Highest Speed
100%
Push to access pump options
Rotates between 1-speed (default), 2-speed and variable speed options
Toggle between Enabled (default) and Disabled Freeze Protection
Adjust the lowest speed desired for variable speed operation
Adjust the highest speed desired for variable speed operation
Move to next menu item
Move to previous/next configuration menu
Move to next menu item or previous/next configuration menu
Move to next menu item
Move to next menu item
if “Variable Speed” is selected
if “Variable Speed” is selected
Freeze Temp
38ºF
Freeze Protect
High Speed
Adjust the desired freeze protection temperature (33ºF - 42ºF)
Toggle between high speed (default) and low speed
Move to previous/next configuration menu
Move to next menu item
if “Freeze Protect” is enabled
if “Freeze Protect” is enabled
and “1-speed Filter” is not selected
Filter Pump
For 2-speed pumps:
When a 2-speed pump is configured, one of
the AUX relays must also
be configured to control the low speed motor winding on the pump.
Refer to the appropriate
sections in the Installation manual for specific information regarding the control logic for 2-
speed and variable speed pump operation.