Hayward H150FDN All models English - Page 41
Troubleshooting Chart
View all Hayward H150FDN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 41 highlights
SECTION 7. TROUBLESHOOTING Troubleshooting Chart: CODE BO IF SF HS HF H-SERIES HEATER DIAGNOSTIC GUIDE FAULT DIAGNOSIS STEP REMEDY Bypass Operation 1. Check state of #2 dip switch on back of control module. This is a normal display when heater is being controlled by a remote thermostat. No service is required. If heater is not being controlled by remote thermostat, change setting of #2 dip switch to "Off" position. 1. Ensure gas supply shutoff valves are open. Ensure that main gas shutoff installed adjacent to heater is open. Ensure that knob on gas valve inside unit is in "On" position. If OK, proceed to step 2. 2. Check for low gas supply pressure. Ensure inlet gas supply pressure exceeds minimum value indicated on rating plate. If OK, proceed to step 3. Ignition Failure 3. Check for faulty igniter wiring or connection. 4. Check for faulty gas valve wiring or connection. Inspect igniter wiring. Ensure igniter plug is securely plugged into back of control module. If OK, proceed to step 4. Inspect gas valve wiring. Ensure wire harness terminals are securely fastened to spade terminals on gas valve. If OK, proceed to step 5. 5. Check for gas valve failure or gas valve relay failure. 1. Measure voltage across gas valve during trial for ignition. If 24 vac is present and gas valve does not open, gas valve is defective. Replace gas valve. 2. If 24 vac is not present, gas valve relay on control module is defective. Replace control module. Temperature Sensor Input Failure 1. Check for faulty wiring or connection. 2. Sensor is defective. Inspect sensor wiring. Ensure sensor is plugged into back of control module. If OK, proceed to step 2. Replace temperature sensor. Maximum Return Water Temperature Exceeded 1. Pool water temperature exceeds 104ºF. 2. Verify that water flow is adequate. Verify set point setting of remote thermostat is at or below 104ºF. If set point setting of remote thermostat is OK, or if heater is not configured for remote thermostat proceed to step 2. Verify that water flow rate to heater is above minimum required. Flame Sense Fault 1. Flame sense failure. Replace igniter. 39