Hayward H400FDN Universal H Series Troubleshooting Guide - Page 58

Service LED ON: AO Code

Page 58 highlights

14. Service LED ON: "AO" Code "AO" Code Replace blower vacuum switch: FDXLBVS1930 Is blower YES damaged? NO YES Are blower vacuum switch wires damaged? NO section B YES Verify 110-125VAC on Inducer off ICB between pins 1-2 (left to right), is voltage present? NO Replace blower: Please refer to (pg. 20) Is vacuum tube YES damaged? NO Correct voltage YES selector plug? NO Install correct plug and replace fuse Replace blower vacuum switch: FDXLBVS1930 Replace ICB: FDXLICB1930 58 Replace vacuum tubing: IDXL2SNT1930 Ohm out blower for 8- 9ohms (before Sept. YES 2010) OR for 4-5ohms (after Sept. 2010), is resistance correct? NO Replace blower: Please refer to (pg. 20) Go to section B

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65

YES
“AO” Code
58
Replace blower:
Please refer to
(pg. 20)
Is blower
damaged?
14. Service LED ON: “AO” Code
Are blower
vacuum switch
wires damaged?
YES
YES
Replace blower
vacuum switch:
FDXLBVS1930
NO
Is vacuum tube
damaged?
NO
Replace
vacuum tubing:
IDXL2SNT1930
YES
NO
YES
Correct voltage
selector plug?
NO
Install correct
plug and
replace fuse
Ohm out blower for 8-
9ohms (before Sept.
2010) OR for 4-5ohms
(after Sept. 2010), is
resistance correct?
Replace blower:
Please refer to
(pg. 20)
NO
Verify 110-125VAC on
Inducer off ICB between
pins 1-2 (left to right), is
voltage present?
YES
NO
Replace blower
vacuum switch:
FDXLBVS1930
Replace ICB:
FDXLICB1930
Go to
section B
section B