Hayward OnCommand Model: ALL MODELS Installation - Page 17
Heater Setpoints in Groups, Super Chlorinate requires external chlorinator - on command
View all Hayward OnCommand manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
A table of functions and their corresponding control parameters are listed below. Function Pool/Spa Pool Filter Lights (standard relay) Lights (dimmer relay) Aux1&2 (standard relay) Aux1&2 (dimmer relay) Valve3 Spa Htr1 Set Pool Htr1 Set Spa Solar Set Pool Solar Set SuperChlr Spa High Spa Low Pool High Pool Low Control Parameter Unaffected, Pool only, Spa only, or Spillover Unaffected, Off, On, High speed, or Low speed Unaffected, Off, or On Unaffected, Off, On, 100%, 80%, 60%, 40%, or 20% Unaffected, Off, or On Unaffected, Off, On, 100%, 80%, 60%, 40%, or 20% Unaffected, Off, or On Unaffected, Off, 65º-104ºF Unaffected, Off, 65º-104ºF Unaffected, Off, 65º-104ºF Unaffected, Off, 65º-104ºF Unaffected, Off, On Unaffected, 20% to Highest speed Unaffected, Lowest speed to 50% Unaffected, 20% to Highest speed Unaffected, Lowest speed to 50% Note that all functions in the table may not be offered. The available functions are dependent on how the OnCommand is configured. Also, under some circumstances, functions will be displayed but can't be changed. Note that the function whose menu you are in, will not be displayed as an option and will automatically turn on when the group is activated. For example, if programming a Group function under the Lights menu, the Lights function will not be offered as an option and the Lights function will automatically turn on with the group. The available control parameters vary with each function. All functions offer "Unaffected", which should be selected if you do not wish to control that particular function within the group. All other parameters will depend on the particular function selected. Heater Setpoints in Groups The OnCommand can be programmed to use alternate heater setpoints (conventional and/or solar) while running a group command. This allows the heater to be set to a higher or lower temperature than normal, while the group is activated. When the group stops, the setpoint will return to its normal setting. Changing the setpoint while the group is running will make the group release the alternate setpoint control and revert back to the normal heater setting. Any changes that are made at that point will affect the normal heater setting. The next time the group is activated, the temperature will return to the group setpoint that was originally programmed in the Configuration Menu. To change the setpoint while the group is running, go to the Settings menu and press the +/- button while "Group Control" is displayed. The setpoint will change and be retained as the new normal heater setpoint. Super Chlorinate (requires external chlorinator) If a Hayward Swimpure or Goldline Aqua Rite chlorinator is used, the OnCommand can be programmed to Super Chlorinate the pool or spa while running a group command. When the group starts, the Super Chlorinate cycle will begin. Super Chlorinate will continue until the preset time expires (see Timers Menu/Super Chlorinate Hours) or until the group turns off. Changing the Super Chlorinate state using the Settings Menu, the Aqua Pod Super Chlorinate button, or a Super Chlorinate assigned Aux/Lights/Valve button will temporarily cancel the group's control of Super Chlorinate until the next time the group is activated. 14