Page 4 highlights

Introduction Before You Begin What's Included Before attempting to install the Pro Logic system, check that the following components have been included in the package: Pro Logic Electronics Unit (3) Temperature sensors with 15 ft. (5m) cable, hose clamp What's NOT Included Some of the additional items that you may need to complete an installation include: Circuit breakers None are included with control-see page 10 and inside of door for suitable breakers Wire 4-conductor cable (electronics unit to remote display/keypad) Wire/conduit for 100A service from main panel to Pro Logic Wire/conduit for filter pump and other high voltage loads Wire for bonding Miscellaneous Utility electrical outlet and weatherproof cover (for mounting on side of Pro Logic) Mounting hardware (screws, etc.) for mounting Pro Logic and remote display/keypad Valves (use standard Hayward, Pentair/Compool, or Jandy valves) Additional valve actuators Accessory Products - Order Separately T-CELL-3 Chlorinator Cell (for pools up to 15k gallons) T-CELL-9 Chlorinator Cell (for pools up to 25k gallons) T-CELL-15 Chlorinator Cell (for pools up to 40k gallons) P-KIT Chlorination plumbing kit containing flow switch and cell unions AQL-CHEM ORP & sense kit AQL-CHEM2(-240) pH dispense kit AQL-WW-P-4 Wired Wall Mount Remote Display AQL-SS-6B-x (x=W/B) Wired Spa Side 6 Function Remote Control, 150ft cable, specify color (white or black) AQL2-POD Handheld Wireless Waterproof Remote with Charging Station (AQL2-BASE-RF required) AQL2-Tx-RF-P-4 Wireless Table Top remote (AQL2-BASE-RF required) AQL2-SS-RF Wireless Spa Side Remote Control (AQ2L-BASE-RF required) AQL2-BASE-RF Base Receiver AQL-DIM Light Dimmer Relay GVA-24 Valve Actuator V&A-xx Valve & Actuator (xx=1P (1.5" pos. seal), -2P (2" pos. seal) NOTE: Before installing this product as part of a saline water purification system in a pool or spa using natural stone for coping or for immediately adjacent patios/decking, a qualified stone installation specialist should be consulted regarding the appropriate type, installation, sealant (if any) and maintenance of stone used around a saline pool with electronic chlorine generator in your particular location and circumstances. NOTE: The use of dry acid (sodium bisulfate) to adjust pool pH is discouraged especially in arid regions where pool water is subject to excessive evaporation and is not commonly diluted with fresh water. Dry acid can cause a buildup of by-products that can damage your chlorinator cell. Installation Steps Details on each installation step are presented on the following pages: 1. Prepare the pool water (page 2) General Water Chemistry Salt 2. Mounting the equipment (page 5) Pro Logic main unit Temperature sensors Remote display/keypad (optional) Valve actuators (if applicable) 3. Plumbing (page 8) General Pool Equipment Turbo Cell Flow Switch 1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

Introduction
Before You Begin
What’s Included
Before attempting to install the Pro Logic system, check that the following components have been included in the
package:
Pro Logic Electronics Unit
(3) Temperature sensors with 15 ft. (5m) cable, hose clamp
What’s NOT Included
Some of the additional items that you may need to complete an installation include:
Circuit breakers
None are included with control—see page 10 and inside of door for suitable breakers
Wire
4-conductor cable (electronics unit to remote display/keypad)
Wire/conduit for 100A service from main panel to Pro Logic
Wire/conduit for filter pump and other high voltage loads
Wire for bonding
Miscellaneous
Utility electrical outlet and weatherproof cover (for mounting on side of Pro Logic)
Mounting hardware (screws, etc.) for mounting Pro Logic and remote display/keypad
Valves (use standard Hayward, Pentair/Compool, or Jandy valves)
Additional valve actuators
Accessory Products - Order Separately
T-CELL-3
Chlorinator Cell (for pools up to 15k gallons)
T-CELL-9
Chlorinator Cell (for pools up to 25k gallons)
T-CELL-15
Chlorinator Cell (for pools up to 40k gallons)
P-KIT
Chlorination plumbing kit containing flow switch and cell unions
AQL-CHEM
ORP & sense kit
AQL-CHEM2(-240)
pH dispense kit
AQL-WW-P-4
Wired Wall Mount Remote Display
AQL-SS-6B-x (x=W/B)
Wired Spa Side 6 Function Remote Control, 150ft cable, specify color (white or black)
AQL2-POD
Handheld Wireless Waterproof Remote with Charging Station (AQL2-BASE-RF required)
AQL2-Tx-RF-P-4
Wireless Table Top remote (AQL2-BASE-RF required)
AQL2-SS-RF
Wireless Spa Side Remote Control (AQ2L-BASE-RF required)
AQL2-BASE-RF
Base Receiver
AQL-DIM
Light Dimmer Relay
GVA-24
Valve Actuator
V&A-xx
Valve & Actuator (xx=1P (1.5” pos. seal), -2P (2” pos. seal)
NOTE: Before installing this product as part of a saline water purification system in a pool or spa using natural stone for
coping or for immediately adjacent patios/decking, a qualified stone installation specialist should be consulted regard-
ing the appropriate type, installation, sealant (if any) and maintenance of stone used around a saline pool with electronic
chlorine generator in your particular location and circumstances.
NOTE: The use of dry acid (sodium bisulfate) to adjust pool pH is discouraged especially in arid regions where pool
water is subject to excessive evaporation and is not commonly diluted with fresh water. Dry acid can cause a buildup
of by-products that can damage your chlorinator cell.
Installation Steps
Details on each installation step are presented on the following pages:
1.
Prepare the pool water
(page 2)
General Water
Chemistry
Salt
2.
Mounting the equipment (page 5)
Pro Logic main unit
Temperature sensors
Remote display/keypad (optional)
Valve actuators (if applicable)
1
3.
Plumbing
(page 8)
General Pool Equipment
Turbo Cell
Flow Switch