Installation Remove power to the pool filter pump before starting this installation. Installation must be performed in accordance with Local and NEC codes. The Control Box must be mounted a minimum of 10 ft. horizontal distance (or more, if local codes require) from the pool, within 3ft from a GFCI outlet, and within 15ft from where the Cell will be installed. Take care to protect the Cell Cap connector pins while handling the Salt & Swim 3C unit during installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Waterproof GFCI Outlet 3 Feet 15 Feet FILTER PUMP Optional Vertical Installation FROM POOL TO POOL Preparing Pool Water To prepare the pool water for Salt & Swim 3C operation, the pool's chemistry must be balanced and salt must be added. This must be done BEFORE activating the Salt & Swim 3C. Some adjustments to your pool chemistry may take several hours, so start the procedure well before you intend to operate the Salt and Swim. To prepare your pool water, follow the instructions on the included Pool Chemistry Quick Start Guide and refer to page 8 of this manual. Adding Salt: Add salt several hours or, if possible, 1 day prior to operating the Salt & Swim 3C . Take care not to exceed the recommended salt level. Measure salt 6-8 hours after adding to the pool. NOTE: If the pool does not have new water, add 1 quart (1 liter) of metal remover and 1 quart (1 liter) of non-copper based algaecide to the pool, per manufacturer's instructions. This ensures a quick, troublefree transfer to the Salt & Swim 3C system. Salt & Swim 3C Installation Follow the step by step instructions located on the Installation Quick Start Guide. Refer to the following sections for more detailed information. 2 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Installation
Remove power to the pool filter pump before starting this installation.
Installation must be performed
in accordance with Local and NEC codes.
The Control Box must be mounted a minimum of 10 ft.
horizontal distance (or more, if local codes require) from the pool, within 3ft from a GFCI outlet, and
within 15ft from where the Cell will be installed.
Take care to protect the Cell Cap connector pins
while handling the Salt & Swim 3C unit during installation. If the supply cord is damaged, it must be
replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Preparing Pool Water
To prepare the pool water for Salt & Swim 3C operation, the pool's chemistry must be balanced and
salt must be added.
This must be done BEFORE activating the Salt & Swim 3C.
Some adjustments
to your pool chemistry may take several hours, so start the procedure well before you intend to oper-
ate the Salt and Swim.
To prepare your pool water, follow the instructions on the included Pool Chemistry Quick Start Guide
and refer to page 8 of this manual.
Adding Salt:
Add salt several hours or, if possible, 1 day prior to operating the Salt & Swim 3C .
Take
care not to exceed the recommended salt level.
Measure salt 6-8 hours after adding to the pool.
NOTE:
If the pool does not have new water, add 1 quart (1 liter) of metal remover and 1 quart (1 liter)
of non-copper based algaecide to the pool, per manufacturer's instructions.
This ensures a quick,
troublefree transfer to the Salt & Swim 3C system.
Salt & Swim 3C Installation
Follow the step by step instructions located on the Installation Quick Start Guide.
Refer to the following
sections for more detailed information.
FROM
POOL
TO
POOL
Waterproof
GFCI
Outlet
Optional
Vertical
Installation
3 Feet
15 Feet
FILTER
PUMP
2
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS