Hayward Summit In Ground Heat Pump 65 000 BTUs Owners Manual
Hayward Summit In Ground Heat Pump 65 000 BTUs Manual
![]() |
View all Hayward Summit In Ground Heat Pump 65 000 BTUs manuals
Add to My Manuals
Save this manual to your list of manuals |
Hayward Summit In Ground Heat Pump 65 000 BTUs manual content summary:
- Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 1
PRINTED IN CANADA OWNER'S Manual 10/2009 - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 2
- Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 3
instructions 8 Using an External Controller 10 Electrical Connections 11 Wiring Diagram 12 Service Analyzer Control 13 Operation 14 Caring for your Pool Heater 15 Initial Startup 16 Meaning of Display Codes 17 Troubleshooting 18 Requesting Assistance or Service - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 4
effort to exceed all industry standards. All SUMMIT pool heat pumps have an electronic board with service analyzer, a titanium heat exchanger tube warranted for 10 years against corrosion and a UV-resistant heating costs. During warmer weather, the pool cover may not be required. 2 OWNER'S MANUAL - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 5
the ownership registration card provided with this guide. The return address is displayed on new information about your heater. Whenever you call to request service for your heater, you must know your complete model safe place for future reference. Service can now be obtained by calling these phone numbers - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 6
General Safety Instructions We care for our customers We have provided important safety messages in this manual and on your heater. Always read and obey all safety messages. IMPORTANT ? The IMPORTANT or injury to a third party. These signs are rare, but are extremely important. 4 OWNER'S MANUAL - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 7
attention to the total alkalinity and TDS. It is highly recommended that you have your pool chemistry checked often by an independent pool store. OWNER'S MANUAL 5 - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 8
Instructions Location The placement of the pool heater is very important in keeping installation costs to a minimum while providing for maximum efficiency of operation, as well as allowing adequate access for service intake and service access. 72" 24" 24" Service access 24" to 36" 6 OWNER'S MANUAL - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 9
. Check the heat pump data label for required maximum breaker size. WARNING The unit must always be powered off before opening the access panel. OWNER'S MANUAL 7 - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 10
and then to the copper rod. Bonding and Plumbing step-by-step instructions 1. A 1/3 lb check valve must be installed between the heater 4. A bypass and shut-off should be installed on all systems for ease of service, maintenance and to balance the water flow. Bypasses must be installed on any system - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 11
Bonding and Plumbing diagram Fig. 2 Chemical feeder Heat Pump Fig. 3 OWNER'S MANUAL 9 - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 12
. 4). • You can now control the operating mode by turning off the switch (open = POOL, closed = SPA.) Fig. 4 External switch Pool (open) Spa (closed) 10 OWNER'S MANUAL - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 13
, and then insert it in the control box. The electrical diagram is located on the lid of the control box as well as in this manual. Power requirements 240 V, 1 PH, 60 Hz Look at the name plate located on the heat pump to know the required amperage. Please refer to your - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 14
OWNER'S MANUAL 12 HPEC-003 Control Board Water sensor Defrost sensor High pressure switch Closed = OK Opened = high pressure Low pressure switch Closed = OK Opened = low pressure - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 15
Service Analyzer Control The control panel is factory set to display the temperature in Fahrenheit degrees. Celsius or Fahrenheit mode ( ) running Heating mode To raise the desired temperature or to change parameters To lower the desired temperature or to change parameters OWNER'S MANUAL 13 - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 16
will be displayed for five seconds, and will then return to the actual pool water temperature in the mode that you have chosen. 14 OWNER'S MANUAL - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 17
Caring for your Pool Heater How to protect your pool heater OWNER'S MANUAL 15 - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 18
immediately start. The compressor will start after a 3 to 4-minute delay. When the compressor is running, the HEATING/CHAUFFAGE indicator located on the right (see "Service Analyzer Control," p. 13) should be lit. At initial startup, it is normal for the unit to run 24 hours a day. It is also normal - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 19
Meaning of Display Codes Service Analyzer Codes Most problems will be detected by the service analyzer and a code will be displayed on the digital display of your heater. Display but the compressor is stopped). This is normal operation when outside temperatures are cold. OWNER'S MANUAL 17 - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 20
Troubleshooting The pool heater is not running. Heat pump control set to OFF. Desired water temperature is reached. Main breaker is tripped. Digital display should indicate FS. The compressor will automatically start again a few minutes after the display stops indicating FS. 18 OWNER'S MANUAL - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 21
electrician to verify your heat pump's power supply by checking over the L1 and L2 connections in the unit's service box. There is water around the unit. While your pool heater is in the heating mode, a large ", p. 3) to obtain the proper authorization for the warranty to apply. OWNER'S MANUAL 19 - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 22
they do not provide service. Before calling for assistance or service, please check the "Troubleshooting" (pp. 18-19) and "Warranty" (pp. 22-23) sections or call your dealer. It may save you the cost of a service call. If you still need help, follow the instructions below. Service can be obtained by - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 23
drained. It is recommended to cover the heat pump to prevent snow from getting inside. A protective winter cover is also offered by your retailer. OWNER'S MANUAL 21 - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 24
services such as inspection, maintenance, or unnecessary service calls due to erroneous operational reports, external valve position, or electrical service and performed by a factory authorized service center, HAYWARD is not liable damages. Parts returned and services performed under terms of this - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 25
that apply to this product. These warranties apply to units shipped after October 1, 2008 Hayward Pool Products, Inc. 620 Division Street Elizabeth, NJ 07207 OWNER'S MANUAL 23 - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 26
Notes 24 OWNER'S MANUAL - Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 27
- Hayward Summit In Ground Heat Pump 65 000 BTUs | Owners Manual - Page 28
![](/manual_guide/products/hayward-summit-heat-pump-owners-manual-ed0462f/1.png)
OWNER’S Manual
PRINTED IN CANADA
10/2009