Hayward Summit In Ground Heat Pump 65 000 BTUs Owners Manual - Page 13

Electrical Connections

Page 13 highlights

Electrical Connections WARNING The installation of the pool heater should be performed by a certified electrician. To connect the electricity, you must unscrew the five screws of the front panel, then slide the electric cable through the knock out located on the left or the right side of the base, and then insert it in the control box. The electrical diagram is located on the lid of the control box as well as in this manual. Power requirements 240 V, 1 PH, 60 Hz Look at the name plate located on the heat pump to know the required amperage. Please refer to your local electrical code for additional wiring requirements. Fig. 5 L1 L2 Ground OWNER'S MANUAL 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Electrical Connections
The installation of the pool heater should be performed by a certified
electrician. To connect the electricity, you must unscrew the five screws of
the front panel, then slide the electric cable through the knock out located
on the left or the right side of the base, and then insert it in the control box.
The electrical diagram is located on the lid of the control box as well as in
this manual.
WARNING
Ground
L1
L2
Fig. 5
Power requirements
240 V, 1 PH, 60 Hz
Look at the name plate loca-
ted on the heat pump to know
the required amperage.
Please refer to your local
electrical code for additional
wiring requirements.
11
OWNER’S MANUAL