Hayward Universal ColorLogic® Universal ColorLogic and CrystaLogic Instal - Page 4

Installation - cm to inches

Page 4 highlights

Installation If replacing an existing light, remove power to the light at the panel before starting this installation. Installation must be performed in accordance with Local and NEC codes. Cord Length and Minimum Required Voltage When installing Universal ColorLogic/CrystaLogic low voltage lights, the length of the cord has an effect on performance. To prevent performance problems, verify the transformer is providing the minimum required voltage according to the table below. To check this voltage, measure the voltage at the transformer while the light is "on" and operating in "white" mode. In some cases, a voltage greater than 12 volts is required due to a long cord run. Some transformers provide higher voltage taps for this purpose; check your transformer manufacturer's installation instructions for details. When using Hayward or other transformers that offer a 14v option, we suggest that you always use the 14 volt tap. Product Total Cord Length Minimum Required from Transformer Voltage at to Light Transformer 12v Universal ColorLogic Pool Light 12v Universal ColorLogic Spa Light 30 ft 50 ft 100 ft 30 ft 50 ft 100 ft 12 - 14 volts 13 - 14 volts 14 volts 12 - 14 volts 13 - 14 volts 14 volts Install Niche (new installations) NOTE: For installation of Hayward niches, see installation instructions provided with the unit. The light fixture must be installed in or on a wall of the pool or spa with the top of the lens not less than 4 inches (10 cm) below the normal water level of the pool except when the fixture is installed in an area of the swimming pool that is not used for swimming. Select a location for the light fixture(s) that will give optimum light dispersion for the pool or spa design. Be sure to consider the direction of emitted light and take care not to point lights directly at the house or outdoor living spaces. 4 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
4
Installation
If replacing an existing light, remove power to the light at the panel before starting this installation. Installation must be performed in accordance with Local
and NEC codes.
Cord Length and Minimum Required Voltage
When installing Universal ColorLogic/CrystaLogic low voltage lights, the length of the cord has an effect on performance. To prevent performance problems,
verify the transformer is providing the minimum required voltage according to the table below. To check this voltage, measure the voltage at the transformer
while the light is “on” and operating in “white” mode. In some cases, a voltage greater than 12 volts is required due to a long cord run. Some transformers
provide higher voltage taps for this purpose; check your transformer manufacturer’s installation instructions for details. When using Hayward or other trans-
formers that offer a 14v option, we suggest that you always use the 14 volt tap.
Install Niche (new installations)
NOTE: For installation of Hayward niches, see installation instructions provided with the unit.
The light fixture must be installed in or on a wall of
the pool or spa with the top of the lens not less than 4 inches (10 cm) below the normal water level of the pool except when the fixture is installed in an area
of the swimming pool that is not used for swimming.
Select a location for the light fixture(s) that will give optimum light dispersion for the pool or spa design.
Be sure to consider the direction of emitted light and take care not to point lights directly at the house or outdoor living spaces.
Product
Total Cord Length
from Transformer
to Light
12v Universal
ColorLogic
Pool Light
12v Universal
ColorLogic
Spa Light
Minimum Required
Voltage at
Transformer
30 ft
50 ft
100 ft
30 ft
50 ft
100 ft
12 - 14 volts
12 - 14 volts
13 - 14 volts
13 - 14 volts
14 volts
14 volts