HP 1606 HP B-series Fabric OS 6.4.1b Release Notes (5697-0886, March 2011-incl - Page 54
On HP StorageWorks DC SAN or DC04 Director, SwFCPortTxType MIB
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 54 highlights
Table 9 Fabric OS 6.4.0 closed defects (continued) Closed defect summary Solution CALD panic occurred on a director and CPs got out of sync, but no failover Fixed in Fabric OS 6.4.0 happened as CALD was in defunct state due to race condition. Workaround prior to upgrade: Manually reboot. Retransmit and Out of order counters displayed in the portshow fciptunnel output do not show correct values. Fixed in Fabric OS 6.4.0 400 Multiprotocol router or multiprotocol router blade non-distruptive firmware Fixed in Fabric OS 6.4.0 upgrade from Fabric OS 6.2.0g to 6.3.0 causes the switch to go Faulty 21. With 1606 Extension SAN Switch or Multiprotocol Extension Blade, FCIP Fixed in Fabric OS 6.4.0 configuration cannot be restored to default setting by using configdefault, even after chassis reboot. Circuit-0 shows InProg after changing 10G tunnel to compression enable in repeated manner during stress to fail testing. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Issuing slotpower off followed by slotpower on usually clears this problem. Interface flapping/ bad cable shows too many ras log messages Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Shut down the port and replace the faulty cable and enable the port. Telnet banner and switchname are not consistent after a new switchname is defined without doing multiple hafailover commands. Can also occur after a standby CP is replaced where the new CP hosts file does not get synchronized with active CP without two hafailover commands. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Use the hostname xyz command when a switchname xyz is used. This issue does not occur with SSH as it does not use the banner. In a rare occurrence, HA synchronization is lost after a switch with trunk Fixed in Fabric OS 6.4.0 ports panics and manual reboot is needed to recover, due to race condition with trunk ports dropping Exchange Fabric Parameter (EFP) response. On HP StorageWorks DC SAN or DC04 Director, SwFCPortTxType MIB does not report the type of CoreBlade's ICL port correctly. Reports as swFCPortTxType.385 unknown(1). Fixed in Fabric OS 6.4.0 Byte Streaming support on 400 multiprotocol router/multiprotocol router blade does not work with third-party optimizers. Fixed in Fabric OS 6.4.0 If the ITL nexus in tape (target containers with initiator) to handle multiplex/ Fixed in Fabric OS 6.4.0 multistream environment is greater than 200, decreased performance is seen Workaround prior to upgrade: for some containers. Reduce the number of IT configuration (target containers with initiators) to 200. No message is displayed when performing slotpoweroff/on on a DC SAN Backbone director. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: These messages are logged into raslog; check raslog for confirmation. The supportsave command did not remove ffdc files. Continued to get Fixed in Fabric OS 6.4.0 ffdc files warning. The file warning message persisted until a second supportsave was issued. Peak data rate is reported as 4096 MB/sec for 2 Gb/s port, which is not Fixed in Fabric OS 6.4.0 possible. In multiprotocol extension blade face plate image in Web Tools Switch View, Fixed in Fabric OS 6.4.0 10GE ports should be renamed as XGE ports. 54