HP 1606 HP B-series Fabric OS 6.4.1b Release Notes (5697-0886, March 2011-incl - Page 57
Solution, Closed defect summary, Workaround prior to upgrade, Active=Save Mode
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
Table 9 Fabric OS 6.4.0 closed defects (continued) Closed defect summary Solution With HP StorageWorks 4/8 and 4/16 SAN Switches, and 4Gb BladeSystem Fixed in Fabric OS 6.4.0 switches for p-Class and c-Class BladeSystem, speed negotiation fails when the port is locked as G_Port, and port cannot come online. In a multi-circuit FCIP tunnel configuration with 1606 Extension SAN switch, or multiprotocol extension blade, circuit failover on 1 Gb tunnels may not fail over to other available circuits with two rate limited circuits. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Disable ARL configuration (use minrate and maxrate options on the tunnel and circuit create commands where minrate and maxrate are the same values. Observed VE tunnel bounce after a hareboot on edge switch EX/VEX_Port Fixed in Fabric OS 6.4.0 (Integrated Routing) under heavy load. This is due to fspftimeout during hafailover resulting from neighbor switch disabling the port caused by the switch taking too long to recover. The sfpshow command displays incorrect information for static values of Fixed in Fabric OS 6.4.0 XFPs. Running Fabric OS commands on the default switch with virtual fabrics enabled, after performing multiple cfgenable commands with TI zones enabled, causes a No space left on device error, and no further Fabric OS commands can be executed. Fixed in Fabric OS 6.4.0 Enhancement to the firmware to have an easy single command to know the Fixed in Fabric OS 6.4.0 state of the encryption status. Unable to activate a new PDCM Matrix with Web Tools. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Activate the same PDCM Matrix from Web Tools, with Active=Save Mode checked from Edit CUP Port Connectivity Configuration window. I2C read values of 0xFF and I2C NACK error case not properly handled, Fixed in Fabric OS 6.4.0 causing Fabric Watch to report improbable/unpredictable SFP values. Multicast data traffic is not forwarded out of snooping multiprotocol router Fixed in Fabric OS 6.4.0 port. The ipAdEntIfIndex values@ 1.3.6.1.2.1.4.20.1.2 must correspond to ifIndex Fixed in Fabric OS 6.4.0 values at 1.3.6.1.2.1.2.2.1.1. Fabric Watch reports that the switch is in Marginal status due to marginal Fixed in Fabric OS 6.4.0 ports when no ports report errors. When running a third-party host scan, the http daemon (weblinker.fcg) terminates and restarts several times, causing a temporary management service interruption. Fixed in Fabric OS 6.4.0 Bad zone config message is displayed in the status message window of Fixed in Fabric OS 6.4.0 the zone admin module when user creates and enables a zone configuration from non-primary FCS switch. Proper error message should be given in this case. Virtual target edit operation (changing the LUN and enabling CHAP) causes Fixed in Fabric OS 6.4.0 the virtual target to disappear from the show. You may see virtual target going offline after an edit operation from Web Tools with iSCSI. When Replicate configuration fails due to some of the parameters, DCFM Fixed in Fabric OS 6.4.0 does not list them in the summary message. Web Tools Does Not Copy Effective Zone to Defined Zone DB During configupload, so Defined Zone will not be updated. Fixed in Fabric OS 6.4.0 Fabric OS 6.4.0 fixes 57