HP 2000i HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911-0 - Page 92
event only applies to non-Active-Active, been inserted from another enclosure.
View all HP 2000i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 92 highlights
Table 14 Event code descriptions and recommended actions (continued) Event Event type Description code Recommended action 59 Warning or The controller detected an error while • For warning events that indicate a disk is informational communicating with the specified SCSI bad, replace that disk. device. The error was detected by the controller, not the disk. This event is logged as a warning for parity errors, and as informational for other errors. • For warning events that indicate an expansion module is bad, replace that expansion module. 60 Informational A disk channel was reset from another initiator or target. 61 Critical A serious error, which might indicate hardware failure, occurred while communicating on the specified disk channel. The controller will attempt to recover. • If the controller recovers, no action is required. • View other logged events to determine other action to take. 62 Informational A spare disk has failed. Replace the failed disk. 65 Critical An uncorrectable ECC error occurred on the buffer memory on startup. The controller is automatically restarted and-if it was operating in active-active mode (i.e., independent cache performance mode was disabled)-its cache data is restored from the partner controller's cache. 67 Informational The controller has identified a new disk or group of disks that constitute a vdisk and has taken ownership of the vdisk. This can happen when disks containing data have been inserted from another enclosure. This event only applies to non-Active-Active controllers. 68 Informational Controller is in a shut-down state. 69 Critical Enclosure reported a general failure. Check the controller module or expansion module for problems such as not being fully inserted, and for bad cables. 71 Informational The controller has started or completed failing over. 72 Informational (Active-active environment) After failover, recovery has started or has completed. 73 Informational (Active-active environment) The two controllers are communicating with each other and cache redundancy is enabled. 74 Informational The FC loop ID for the specified vdisk was changed to be consistent with the IDs of other vdisks. This can occur when disks containing a vdisk are inserted from an enclosure having a different FC loop ID. This event is also logged by the new owning controller after vdisk ownership is changed. 92 Event code reference