HP 8/80 Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June - Page 122
TABLE 10, To enable signed firmware download on a disabled switch
View all HP 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 122 highlights
2 configure System Settings The following table lists system settings. TABLE 10 System settings Field Type system.blade.bladeFaultOn Number HwErrMsk Default 0x0 Range 0x0 to 0xffff system.blade.bladeFaultOnHwErrMsk If this field is set to a value other than 0, then any nonfatal HW ASIC data parity error causes the problem blade to be powered off. Examples To enable signed firmware download on a disabled switch: switch:admin> configure Configure... Fabric parameters (yes, y, no, n): [no] Virtual Channel parameters (yes, y, no, n): [no] F-Port login parameters (yes, y, no, n): [no] Zoning Operation parameters (yes, y, no, n): [no] RSCN Transmission Mode (yes, y, no, n): [no] Arbitrated Loop parameters (yes, y, no, n): [no] System services (yes, y, no, n): [no] Portlog events enable (yes, y, no, n): [no] ssl attributes (yes, y, no, n): [no] rpcd attributes (yes, y, no, n): [no] cfgload attributes (yes, y, no, n): [no] y Enforce secure config Upload/Download (yes, y, no, n): [no] Enforce signature validation for firmware (yes, y, no, n): [no] y webtools attributes (yes, y, no, n): [no] System (yes, y, no, n): [no] [output truncated] :See Also configDefault, configShow, ipAddrSet, portCfgLongDistance, switchDisable, switchEnable, upTime 96 Fabric OS Command Reference 53-1000599-02