HP 8000 Technical Reference Guide: HP Compaq 8000 Elite Series Business Deskto - Page 77

Table 7-2., SFF 240-Watt Power Supply Unit Specifications

Page 77 highlights

Power and Signal Distribution Table 7-2 lists the specifications of the 240-watt power supply used in the SFF unit. Table 7-2. SFF 240-Watt Power Supply Unit Specifications Input voltage: 115 VAC 230 VAC Line Frequency Input (AC) Current Requirement (100 VAC rms @ 60 Hz) Output voltage (VDC): +12 Vmain +12 Vcpu +12 Vsb (aux) -12 V AC Range or Min. Current Max. Surge DC Regulation Loading [1] Current Current [2] 90-140 VAC 180-264 VAC 47-63 Hz -- -- -- -- -- -- -- -- 5.5 A rms -- 11.62 to 12.57 11.62 to 12.57 11.06 to 11.74 -10.8 to -13.2 0.5 A 1 A 0.1 A 0 A 14 A 12 A 1.3 A 0.15 A 16 A 16 A 1.5 A 0.5 A Max. Ripple -- --- 120 mV 120 mV 120 mV 120 mV NOTES: Total continuous power should not exceed 240 watts. Total surge power (

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

Technical Reference Guide
www.hp.com
7-3
Power and Signal Distribution
Table 7-2 lists the specifications of the 240-watt power supply used in the SFF unit.
NOTES:
Total continuous power should not exceed 240 watts. Total surge power (<10 seconds w/duty cycle < 5 %) should not exceed
265 watts.
[1] The minimum current loading figures apply to a PS On start up only.
[2] Maximum surge duration for +12Vcpu is 1 second with 12-volt tolerance +/- 10%.
Table 7-3 lists the specifications for the 320-watt power supply used in the CMT form factor.
NOTES:
Total continuous output power should not exceed 320 watts.
[1] Minimum loading requirements must be met at all times to ensure normal operation and specification compliance.
[2] Maximum surge duration for +12Vcpu is 1 second with 12-volt tolerance +/- 10%.
Table 7-2.
SFF 240-Watt Power Supply Unit Specifications
AC Range or
DC Regulation
Min.
Current
Loading [1]
Max.
Current
Surge
Current [2]
Max.
Ripple
Input voltage:
115 VAC
230 VAC
90–140 VAC
180–264 VAC
--
--
--
--
Line Frequency
47–63 Hz
--
--
--
--
Input (AC) Current Requirement
(100 VAC rms @ 60 Hz)
--
--
5.5 A rms
--
--
Output voltage (VDC):
+12 Vmain
+12 Vcpu
+12 Vsb (aux)
–12 V
11.62 to 12.57
11.62 to 12.57
11.06 to 11.74
–10.8 to –13.2
0.5 A
1 A
0.1 A
0 A
14 A
12 A
1.3 A
0.15 A
16 A
16 A
1.5 A
0.5 A
120 mV
120 mV
120 mV
120 mV
Table 7-3.
CMT 320-Watt Power Supply Unit Specifications
AC Range or
DC Regulation
Min.
Current
Loading [1]
Max.
Current
Surge
Current [2]
Max.
Ripple
Input voltage:
115 VAC
230 VAC
90–140 VAC
180–264 VAC
--
--
--
--
Line Frequency
47–63 Hz
--
--
--
--
Input (AC) Current Requirement
(100 VAC rms @ 60 Hz)
--
--
5.5 A rms
--
--
Output voltage (VDC):
+12 Vmain
+12 Vcpu
+12 Vsb (aux)
–12 V
11.62 to 12.57
11.62 to 12.57
11.06 to 11.74
–10.8 to –13.2
0.5 A
1 A
0.1 A
0 A
16 A
14 A
1.3 A
0.15 A
18 A
18 A
1.5 A
0.5 A
120 mV
120 mV
120 mV
120 mV