HP Brocade BladeSystem 4/24 HP StorageWorks B-series Data Center Fabric Manage - Page 32
DCFM Migration and Transition Guide, FrameResizeState Enable
View all HP Brocade BladeSystem 4/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Closed defect summary Solution Slot number does not show uniform values across the Port, Connection, and Trunk Properties tables. Fixed in DCFM 10.3.0 Audit logs do not contain entries for FrameResizeState Enable/ Disable when the CLI is used for configurations. Fixed in DCFM 10.3.0 A Communication failure with server error message appears on the DCFM client when the server is still running, and users cannot Fixed in DCFM 10.3.0 log in to the DCFM client. Utilization legend flickers when it is detached, and users cannot see the utilization range. Fixed in DCFM 10.3.0 Unable to activate High Integrity Fabric (HIF) in a mixed fabric containing an Mi10K virtual fabric. An error, timeout message appears. Fixed in DCFM 10.3.0 When you deactivate HIF in a mixed fabric, a Deactivate not supported error message appears, even though HIF is supported for a mixed fabric. Fixed in DCFM 10.3.0 System Report (SYR) generation fails when the SYR filename uses the chassis WWN in the report. Fixed in DCFM 10.3.0 An Unknown error occurs while discovering a FOS-based switch when the firewall setting is opened. You cannot discover the switch even if the firewall is configured and all ports are opened. Fixed in DCFM 10.3.0 If you attempt to discover a switch that is not currently present in the DCFM server, an inaccurate seed switch already present message appears. Fixed in DCFM 10.3.0 Setting the Switch Connection Control (SCC) policy is shown as an option when activating HIF for a M-EOS-based only fabric, which is inaccurate because setting the SCC policy is not applicable for M-EOSbased switches. Fixed in DCFM 10.3.0 Users cannot log in to the DCFM client after it is killed with Task Manager in DCFM Professional. A Login Failed, only one client is allowed error message appears. Fixed in DCFM 10.3.0 An HBA connected to an Access Gateway switch is displayed in the Topology when an M-EOS-based switch is the seed switch. This can mislead users. Fixed in DCFM 10.3.0 No source name or source address is displayed in the Master Log when the real time graph fails for an EE monitor pair. The user cannot Fixed in DCFM 10.3.0 identify the source of the error message. After deactivating the Zone configuration with TI zone with HP StorageWorks 2408 FCoE Converged Network Switch, the TI zones reappear Fixed in DCFM 10.3.0 in the Active Zone Configuration tab after a few minutes. When installing DCFM Professional, the Server Port Configuration window correctly states that 13 consecutive port numbers are required. The DCFM Migration and Transition Guide incorrectly states that 14 consecutive port numbers are required. Fixed in DCFM 10.3.0 32