HP Cisco MDS 8/24c Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Rel - Page 36

Resolved Caveats, DDTS Number, NX-OS Software Release Open, or Resolved

Page 36 highlights

Caveats Send documentation comments to [email protected] Table 16 Open Caveats and Resolved Caveats Reference (continued) DDTS Number Severity 4 CSCtn68418 NX-OS Software Release (Open or Resolved) 5.2(1) NX-OS Software Release (Open or Resolved) 5.2(2) O R Resolved Caveats • CSCtq76711 Symptom: The 8-port FCoE module (DS-X9708-K9) fails to boot up after it is power cycled. This issue might be seen if there are enough local routes to exhaust the hardware table space on the FCoE module. Workaround: This issue is resolved. • CSCtq79432 Symptom: On the storage VDC of the switch, the default gateway and the IP address of the switch may not be reachable if they are configured using the setup script. This issue can occur when you use the setup script to configure the default gateway and IP address. The default gateway and IP address should be configured manually in the "default" VRF. Workaround: This issue is resolved. • CSCtr24502 Symptom: Following a switch reload or a module reload, throughput drops with local switching enabled because the local switching configuration is lost after the reload. Workaround: This issue is resolved. • CSCtr27068 Symptom: The port-group monitor feature is disabled on the Cisco MDS 9000 48-port 8-Gbps Advanced Fibre Channel switching module (DS-X9248-256K9). Workaround: This issue is resolved. • CSCtr27150 Symptom: The port-group monitor feature is disabled on the 32-port 8-Gbps Advanced Fibre Channel switching module (DS-X9232-256K9). Workaround: This issue is resolved. • CSCtr36554 Symptom: The feature manager causes high CPU usage on the standby supervisor. This issue occurs when the feature manager gets into a loop of sending messages to itself. Workaround: This issue is resolved. • CSCts68756 Symptom: When configuring user-defined commands for alert-groups, the "too big pss key" error message or the "value size" error message appears. In addition, the CFS Call Home commit fails. Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.2(2) 36 OL-25090-02

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

Send documentation comments to [email protected]
36
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.2(2)
OL-25090-02
Caveats
Resolved Caveats
CSCtq76711
Symptom
: The 8-port FCoE module (DS-X9708-K9) fails to boot up after it is power cycled. This
issue might be seen if there are enough local routes to exhaust the hardware table space on the FCoE
module.
Workaround
: This issue is resolved.
CSCtq79432
Symptom
: On the storage VDC of the switch, the default gateway and the IP address of the switch
may not be reachable if they are configured using the setup script. This issue can occur when you
use the setup script to configure the default gateway and IP address. The default gateway and IP
address should be configured manually in the “default” VRF.
Workaround
: This issue is resolved.
CSCtr24502
Symptom
: Following a switch reload or a module reload, throughput drops with local switching
enabled because the local switching configuration is lost after the reload.
Workaround
: This issue is resolved.
CSCtr27068
Symptom
: The port-group monitor feature is disabled on the Cisco MDS 9000 48-port 8-Gbps
Advanced Fibre Channel switching module (DS-X9248-256K9).
Workaround
: This issue is resolved.
CSCtr27150
Symptom
: The port-group monitor feature is disabled on the 32-port 8-Gbps Advanced Fibre
Channel switching module (DS-X9232-256K9).
Workaround
: This issue is resolved.
CSCtr36554
Symptom
: The feature manager causes high CPU usage on the standby supervisor. This issue occurs
when the feature manager gets into a loop of sending messages to itself.
Workaround
: This issue is resolved.
CSCts68756
Symptom
: When configuring user-defined commands for alert-groups, the “too big pss key” error
message or the “value size” error message appears. In addition, the CFS Call Home commit fails.
Severity 4
CSCtn68418
O
R
Table 16
Open Caveats and Resolved Caveats Reference (continued)
DDTS Number
NX-OS Software Release (Open
or Resolved)
NX-OS Software Release (Open
or Resolved)
5.2(1)
5.2(2)