Using a utility tool, lift up evenly across the module to remove the camera module
View all HP ENVY m7-n000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
2. Before replacing the display panel assembly, thoroughly clean all adhesive residue from the display panel (1). Remove the protective backing from the new adhesive strips (2), align the strips to the correct locations on the panel(3), and then press down for 3 seconds to attach the strips to the display panel assembly (4). 3. If you need to remove the camera module: a. Disconnect the camera cable from the reverse ZIF connector (1). b. Using a utility tool, lift up evenly across the module to remove the camera module (2). and then peel the module up from the display back cover (3). c. Peel the IR board cable from the display back cover (4). d. Remove the camera module and cable (5). The camera module is available as spare part number N13382-001. Display assembly 55